4-3
Section
Trigger Inputs and Output Format
52
Send
<Footer>
<Unit No.>
Receive
Data is output from the V530-R150 without polling commands.
<Header >
<Unit No.>
<Scene No.>
<Footer>
Switch the Scene (@MS Unit No. Scene No.) 1:N Connection
Switches the scene number to be displayed.
Send
<Footer>
<Scene No.>
<Unit No.>
Receive
Data is output from the V530-R150 without polling commands.
Correctly switched:
<Header >
<Unit No.>
OK
<Footer>
Incorrectly switched:
<Header >
<Unit No.>
ER
<Footer>
4-3-2
Communications Mode: Host Link
Command Table
Command Code
Function
10
One shot reading
11
Start continuous reading
12
Stop continuous reading
20
Switch to a specified scene number
21
Increase the displayed scene number by one
22
Decrease the current scene number by one
23
Read the scene number currently displayed