background image

Bar  Code  CCD  Scan-

ner

Operation  Manual

Summary of Contents for 2008

Page 1: ...Bar Code CCD Scan ner Operation Manual...

Page 2: ...interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a c...

Page 3: ...2 Installing Keyboard Wedge Interface CCD Scanner 5 3 Installing RS232 Interface CCD Scanner 7 4 Quick Install Programming 11 5 Custom Programming 15 6 Troubleshooting 43 Appendix I Specifications 45...

Page 4: ...2...

Page 5: ...nd may be reconfigured at any time to meet future needs and changing applica tion requirements A built in memory backup circuit enables the CCD to retain programmed data during any power outage Step 2...

Page 6: ...ner with RS232 cable 1 pce Operation Manual Before You Install Step 3 Determine installation mode If you purchased with a keyboard wedge interface turn to Chapter 2 for installation instructions If yo...

Page 7: ...end of the T connector of the cable provided Plug the male end of the T connector into the keyboard port of your computer Review the installation diagram on the following page Step 1 Turn off your com...

Page 8: ...he com puter and the scanner keyboard type The scanner will activate with a beep indicating a successful installation You may now test your scanner by scanning any bar code The bar code number will ap...

Page 9: ...nec tion requires 5V DC to be input from the computer directly Another one with DC JACK on the cable is named XXXXR9R of its model This connection requires 8V 14V DC to be input from the external adap...

Page 10: ...scanner should activate with a beep indicating a successful installation Connect the 9 pin female connector DB9F with DC jack to the male equivalent DB9M port on your computer Provide power to the DC...

Page 11: ...written in BASIC is sufficient for this purpose 10 open COM1 9600 N 8 1 cd ds cs as 1 20 input 1 A 30 print A 40 go to 20 With this program running the number of any bar code you scan will appear on...

Page 12: ...10...

Page 13: ...rd character set No start stop character transmission Check digit disabled Standard character set Start stop characters A B C D transmitted Keyboard Wedge RS232 Code 39 Quick Install Programming This...

Page 14: ...A FNC 2 concatenation disabled Check digit calculated but not transmitted Fixed code length of 10 digits Start Stop characters 2 bars transmitted Check digit disabled Fixed code length of 10 digits C...

Page 15: ...g page in order The reading of this code installs the default values for ALL parameters NOTE Program enter into programming mode If your requirements exactly match all of the default settings you have...

Page 16: ...ter 5 and follow the proce dure for custom programming the special features which you require Likewise if only a few parameters need to be changed for a new application there is no need to totally rec...

Page 17: ...e Scan Program at the bottom left of each page Scan your specific choice Scan End at the bottom right of each page The default value for each parameter is indicated by asterisks and bold typeface e g...

Page 18: ...27 28 Interleaved 2 of 5 29 30 UPC and EAN 31 34 Codabar 35 36 Code 128 37 38 Code 93 38 Bar Code Identifiers 39 41 RS232 Parameters Bar Code Symbologies Buzzer Setting 1 KHz 120 mSec 2 KHz 120 mSec...

Page 19: ...or hand free operation If you program this mode the scanner light up always but this mode does not allow the same bar code to be read twice REPEAT MODE This mode is similar to the Auto Scan Mode but a...

Page 20: ...e host computer Adjusting the inter message and inter character delay may improve data transmission when operating in conjunction with a fast computer or incompatible DOS version None 100 msec 500 mse...

Page 21: ...of the code transmitted The maximum length is ten digits The pre set default value is for no header nor trailer If you wish to program these parameters you must first enable reading of the Full ASCII...

Page 22: ...ation the scanner must be configured to match your keyboard emulation and language A message suffix feature appends any message from the scanner with the pro grammed character IBM 3472 3477 For Asian...

Page 23: ...Parameters IBM AT U S English IBM XT U S English IBM AT German IBM XT German IBM AT French IBM XT French IBM AT Spanish IBM XT Spanish IBM AT Itlian IBM XT Itlian IBM AT Swedish IBM XT Swedish IBM AT...

Page 24: ...22 Message Suffix keyboard wedge mode None Enter Horizontal Tab Field Exit Field Advance Return Program End Keyboard Wedge Parameters...

Page 25: ...rameters including handshaking baud rate data bit stop bit parity and message suffix must be configured to match the requirements of your system 500 mSec 200 mSec 100 mSec 300 mSec ACK NAK handshaking...

Page 26: ...24 Program End 600 1200 2400 4800 9600 19200 2 sec 1 sec 3 Sec 5 Sec Infinity Baud Rate RS232 Parameters...

Page 27: ...25 Parity Program End Even Odd Space None Data Bit 7 8 Stop Bit 2 1 RS232 Parameters...

Page 28: ...26 Program End Message Suffix RS232 mode None CR LF CR LF ETX EOT Horizontal Tab RS232 Parameters...

Page 29: ...Code 39 Symbology Code 39 is the most popular bar code symbology for ID inventory and tracking purposes The code is alphanumeric and may vary in length from 3 to 32 digits Program End Enable Code 39 D...

Page 30: ...calculation and transmission of the check digit are optional Disabled Calculated and Transmitted Code 39 Start Stop Character Calculated but not Transmitted This feature enables the transmission of s...

Page 31: ...ry compact in that both bars and spaces encode information Enable Interleaved 2 of 5 Disable Interleaved 2 of 5 The check digit function is recom mended when using a variable code length The calculati...

Page 32: ...to 32 digits even number only Scan Program Scan Variable Scan End And if chosen the use of the check digit is recommended The option of changing from the pre set length of 10 is also available To do...

Page 33: ...ed mainly in retail applications Both are fixed length numeric bar codes which use a check digit Enable UPC and EAN Disable UPC and EAN UPC and EAN Formats All EAN 8 or EAN 13 UPC A and UPC E UPC A an...

Page 34: ...um Program End Disable 5 Characters 2 Characters 2 or 5 Characters UPC EAN Transformations UPC A to EAN 13 Not Allowed UPC E to UPC A Not Allowed UPC A to EAN 13 Allowed UPC E to UPC A Allowed Bar Cod...

Page 35: ...Transmitted EAN 13 Check Digit Not Transmitted EAN 8 Check Digit Transmitted EAN 8 Check Digit Not Transmitted UPC A Check Digit Transmitted UPC A Check Digit Not Transmitted UPC E Check Digit Transmi...

Page 36: ...racter Not Transmitted UPC A Leading Character Transmitted The leading characters can be used to recognize the type of UPC code received by the host computer Bar Code Symbologies UPC E Leading Charact...

Page 37: ...mbologies Codabar is an numeric bar code used in libraries and medical settings It varies in length from 3 to 32 digits Disable Codabar Enable Codabar Codabar Start Stop Character Transmission DC1 DC4...

Page 38: ...36 Codabar Length MAX LEN MIN LEN Set Program End Bar Code Symbologies...

Page 39: ...r inch Owing to the high density it is important the bar code printing be of high quality Code 128 varies in length from 3 to 32 digits Enable Code 128 Disable Code 128 Disable Enable Code 128 FNC 2 C...

Page 40: ...EN Set Code 93 Symbology Code 93 is a compact alphanumeric symbology often used on small electronic components Its code length may vary from 3 to 32 digits Enable Code 93 Disable Code 93 Code 93 Lengt...

Page 41: ...smitted by the Series CCD scanner The default value under the Quick Install option disables bar code identification However a series of letters has been pre assigned to the bar code symbologies itemiz...

Page 42: ...ASCII character set under the Code 39 configuration The programming procedure is then as follows Scan Program Scan Enable Scan the bar code symbology you wish identify Scan the desired characters in...

Page 43: ...41 UPC A EAN 13 EAN 8 Code 93 Code 39 Codabar Code 128 Standard 2 of 5 Interleaved 2 of 5 Custom Bar Code Identifier Program End Enable Code Identifiers UPC E Set Bar Code Symbologies...

Page 44: ...42...

Page 45: ...ing Please refer to 26 40 for different bar code symbolo gies setting procedure Wrong setting with the Keyboard Type Emulation or Keyboard Language Please refer to the keyboard wedge parameters settin...

Page 46: ...44 Troubleshooting...

Page 47: ...IBM 5550 IBM 347x IBM 3196 The RS232 interface CCD scanner RS232C interface with 9 pin female connectors Automatically recognizes UPC EAN and JAN UPC and EAN Addendum Code 39 and Full ASCII Code 39 St...

Page 48: ...rature 0O C to 50O C Storage temperature 20O C to 60O C Humidity 20 to 95 non condensing Ambient Ligh Rejection 1500 Lux Max Flourescence 800 Lux Max Sunlight Specifications programmable parameters co...

Page 49: ...47 25 pin DB Female Connect For RS232C Interface 2 RX 3 TX 4 CTS 5 RTS 7 GND MODEL 20XXR2R Connector Pin Assignments for connect to terminal...

Page 50: ...48...

Page 51: ...49 A Appendix II ASCII Code Table NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1...

Page 52: ...50 ASCII Code Table DC2 ESC DC3 FS GS DC4 EM CAN ETB US SYN RS NAK SUB SP...

Page 53: ...51 ASCII Code Table 2 1 0 5 4 3...

Page 54: ...52 6 G F E D C B 9 A 8 7 ASCII Code Table...

Page 55: ...53 P Y X O W N V M U L T K S J R I Q H ASCII Code Table...

Page 56: ...54 ASCII Code Table b k a j i h _ g f e d c Z...

Page 57: ...55 ASCII Code Table t s r z q y p x o w n v m u l...

Page 58: ...56 DEL ASCII Code Table...

Page 59: ...ISSUED NOV 97 V 7...

Reviews: