6-4
Section
System
161
6-4
System
6-4-1
Communications Method
Sets communications methods when communicating to external
devices via terminal blocks or RS-232C.
•
When communicating in normal format via RS-232C:
Set the communications method for
RS-232C and Normal.
•
When communicating with host link via RS-232C:
Set the communication method for
RS-232C and Host link.
•
When inputting trigger or outputting reading results (OK/NG) to
the OK/NG terminals on terminal blocks:
Set the communications method for
Terminal block.
RS-232C
Baud rate
:33400bps
j
Data length
:
8bit
j
Parity bits
:
None
j
Stop bits
:
1bit
j
Header
:
None
j
Footer
:
CR
j
FCS
:
OFF
j
Attach digit no.
:
OFF
j
Mode :
Normal
j
End
A
H
B
C
D
E
F
G
I
1
Select 2400, 4800, 9600, 19200, or 38400 (bps).
(Default setting: 38400)
2
Select 7 or 8 (bits). (Default setting: 8)
3
Select None, Odd, or Even. (Default setting: None)
4
Select 1 or 2 (bits). (Default setting:1)
5
Select None, STX, or ESC. (Default setting: None)
6
Select CR, LF, or CR+LF. (Default setting: CR)
7
Select OFF or ON. (Default setting: OFF)