AXIOM
™
Line Bar Code Reader
Quick Reference Guide
AXIOM
|
Line Bar Code Readers
|
Laser
Introduction
The AXIOM is designed for easy installation and setup. Use this guide as a cross reference to
locate the content you need in the
AXIOM/AXIOM-X Product Line Manual
.
Safety Precautions
(Chapter 2)
Observe all safety precautions regarding:
•
Power, electrical, grounding (p. 13)
•
Electrostatic discharge (ESD) (p. 14)
•
Laser Exposure (p. 15)
Mechanical Installation
(Chapter 3, see also mounting illustrations, side 2)
1. Assemble mounting structure according to your mounting diagram, if applicable.
2. Mount wiring base in the defined location using orientation consideration
as a guideline (p. 19-21). A universal mounting bracket is available (p. 24-26).
3. Mount the Trigger Photoeye and reflector (p. 30).
4. Mount the tachometer, if applicable (p. 33).
5. Install optional I/O modules into wiring base, if applicable (p. 34-35).
Electrical Installation
(Chapter 4, Appendix E)
Use the wiring base label
(see side 2)
as a reference when performing electrical
installation.
1. Properly ground wiring base to protective earth (PE) ground (p. 46-47).
2. Connect power supply to wiring base
and perform polarity check (p. 51-53).
3. Connect Trigger photoeye to Trigger
terminal blocks (p. 54).
4. Connect tachometer to TACH terminal
blocks and use ferrite clamps (p. 55-56).
5. Connect RS232/422 communications
to SERIAL COM terminals (p. 57).
6. Connect Ethernet communications
to ETHERNET terminals (p. 58).
7. Connect I/O module wiring to I/O 1 through I/O 4, as required (p. 59-60).
8. Install scan head to wiring base as outlined in Chapter 3 (p. 39-42).
Setup and Operations
(Chapter 5 and 6)
1. Use the first-time startup / setup procedures and operations checklist (p. 118-119).
2. Use AXCESS and a setup cable (p. 71) or network connection (p. 73) to modify
operating parameters (p. 75-104).
3. M
onitor operations using AXIOM Monitor and Log Viewer diagnostics (p. 124).
4. Backup parameters to the wiring base using AXCESS or the connector panel (p.104).
An AXIOM typically includes:
• AXIOM Scan Head
• Wiring Base
• Power Supply
Options that may be included:
• Universal Mounting Bracket
• Trigger Photoeye
Time Required:
45 minutes / unit
• Mechanical installation (30 minutes)
• Electrical installation (15 minutes)
• Setup
(see AXCESS Quick Reference Guide)
Tools Required:
• Phillips Long-Handled #2 Screwdriver
• Slotted screwdriver (1/8”)
• Adjustable Wrench (open-ended)
• Tape Measure
Quick Start References:
• AXIOM/AXIOM-X Product Line Manual
• Mounting structure drawings
Other Useful References:
• AXCESS for AXIOM Quick Reference Guide
• Interconnect drawings located in
AXIOM/AXIOM-X Manual, App. E (p.209):
107480 - Controller/Client with Tach
107481 - Controller/Client/Client w/Tach
107482 - Start/End Trigger Photoeyes
107483 - Stack Light with Internal Relays
NOTICE: Application-specific documenta-
tion provided with your equipment may
supersede the information provided here.
Installing Scan Head to Wiring Base
Observe Laser Safety Warnings on AXIOM