3-13
H
Setting n001 for Parameter Write-prohibit Selection/Parameter
Initialization
·
No data can be written to n176 for parameter copy function selection unless the default
setting is changed. To write data to this parameter, set n001 for parameter write-pro-
hibit selection/parameter initialization to 4.
Parame-
ter
Register
Name
Description
Setting
range
Unit of
setting
Default
setting
Chan-
ges dur-
ing
opera-
tion
n001
0101
Parame-
ter write-
prohibit
selection/
parame-
ter initial-
ization
Used to prohibit parameters
to be written, sets parame-
ters, or change the monitor
range of parameters.
Used to initialize parameters
to default settings.
0: Sets or monitor parameter
n001. The parameters within
a range from n002 to n179
can be monitored only.
1: Sets or monitor the param-
eters within a range from
n001 to n49 (i.e., function
group 1 settings).
2: Sets or monitor the param-
eters within a range from
n001 to n79 (i.e., function
groups 1 and 2 settings).
3: Sets or monitor the param-
eters within a range from
n001 to n119 (i.e., function
groups 1 through 3 settings).
4: Sets or monitor the param-
eters within a range from
n001 to n179 (i.e., function
groups 1 through 4 settings).
5: Same operation as set to
4, but RUN command is ex-
cepted in program mode.
6: Clears the error log.
8: Initializes parameters to
default settings in 2-wire
sequence.
9: Initializes parameters in
3-wire sequence.
10:For the USA, initializes
parameter in 2--wire se-
quence.
11:For the USA, initializes
parameter in 3--wire se-
quence.
0 to 9
1
1
No
Preparing for Operation and Monitoring
Chapter 3
Содержание SYSDRIVE 3G3MV A2002
Страница 1: ...USER S MANUAL SYSDRIVE 3G3MV Multi function Compact Inverter Cat No I527 E2 02...
Страница 15: ...Chapter 1 Overview 1 1 Function 1 2 Nomenclature 1 3 New Features 1...
Страница 24: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Страница 69: ...Chapter 3 Preparing for Operation and Monitoring 3 1 Nomenclature 3 2 Parameter Copy and Verify Function 3...
Страница 89: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Страница 286: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9...
Страница 296: ...9 11 D 3G3MV PFI1040 E Three 5 dia holes Four M4 holes for Inverter mounting use Specifications Chapter 9...
Страница 298: ...9 13 D 3G3MV PFI2030 E Four M4 holes for Inverter mounting use Three 5 dia holes Specifications Chapter 9...
Страница 299: ...9 14 D 3G3MV PFI2050 E Four M5 holes for Inverter mounting use Three 6 dia holes Specifications Chapter 9...
Страница 301: ...9 16 D 3G3MV PRS3030V Four M5 holes for Inverter mounting use Three 6 dia holes Specifications Chapter 9...
Страница 311: ...Chapter 10 List of Parameters 10...
Страница 342: ...Chapter 11 Using the Inverter for a Motor 11...
Страница 348: ...Appendix A Standard Models...