10-22
Para
me-
ter
No.
Ref-
er-
ence
page
Chan-
ges dur-
ing
opera-
tion
Defaul
t set-
ting
Unit
of
set-
ting
Set-
ting
range
Description
Name
Reg-
ister
No.
n115
0173
Stall pre-
vention
level auto-
matic sup-
pression
selection
Selects whether or not to automatically de-
crease the level for stall prevention during op-
eration if the frequency lies in a constant out-
put range exceeding the frequency set in n013
for max. voltage frequency (a range greater
than the rated motor frequency).
0: Automatic suppression function disabled
(the value of n094 is valid for any frequency)
1: Automatic suppression function enabled.
Note
The operation level is decreased by n094
´
(max. voltage frequency/output fre-
quency).
Note
The stall prevention function during op-
eration operates according to the accel-
eration/deceleration time set in n116.
0, 1
1
0
No
6--33
n116
0174
Stall pre-
vention ac-
celeration/
decelera-
tion time
setting
Sets the acceleration/deceleration time for the
stall prevention function during operation.
0: Accelerates or decelerates according to
acceleration/deceleration time 1 or 2,
whichever is selected.
1: Accelerates or decelerates according to
acceleration/deceleration time 2.
(n021/n022).
Note
When a faster (or slower) acceleration/
deceleration time is desired, set this pa-
rameter to “1” and set the desired accel-
eration/deceleration time for stall preven-
tion operation in acceleration/decelera-
tion time 2.
0, 1
1
0
No
6--34
n117
0175
Undertor-
que detec-
tion selec-
tion
0: Undertorque detection not provided
1: Detected during constant-speed running.
Operation continues after detection.
2: Detected during constant-speed running.
Operation stops during detection.
3: Detected during running. Operation
continues after detection.
4: Detected during running. Operation stops
during detection.
(1)To detect undertorque at accel/decel, set to
3 or 4.
(2)To continue the operation after undertorque
detection, set to 1 or 3.
(3)To stop the inverter by a fault at undertorque
detection, set 2 or 4.
Note
Applicable
for
software
version
No. 010024 or later.
0,1
1
0
List of Parameters
Chapter 10
Содержание SYSDRIVE 3G3MV A2002
Страница 1: ...USER S MANUAL SYSDRIVE 3G3MV Multi function Compact Inverter Cat No I527 E2 02...
Страница 15: ...Chapter 1 Overview 1 1 Function 1 2 Nomenclature 1 3 New Features 1...
Страница 24: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Страница 69: ...Chapter 3 Preparing for Operation and Monitoring 3 1 Nomenclature 3 2 Parameter Copy and Verify Function 3...
Страница 89: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Страница 286: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9...
Страница 296: ...9 11 D 3G3MV PFI1040 E Three 5 dia holes Four M4 holes for Inverter mounting use Specifications Chapter 9...
Страница 298: ...9 13 D 3G3MV PFI2030 E Four M4 holes for Inverter mounting use Three 5 dia holes Specifications Chapter 9...
Страница 299: ...9 14 D 3G3MV PFI2050 E Four M5 holes for Inverter mounting use Three 6 dia holes Specifications Chapter 9...
Страница 301: ...9 16 D 3G3MV PRS3030V Four M5 holes for Inverter mounting use Three 6 dia holes Specifications Chapter 9...
Страница 311: ...Chapter 10 List of Parameters 10...
Страница 342: ...Chapter 11 Using the Inverter for a Motor 11...
Страница 348: ...Appendix A Standard Models...