9-5
Max. applicable motor
capacity (kW)
0.37
0.55
1.1
1.5
2.2
3.0
4.0
5.5
7.5
Output
specifi-
cations
Rated output
capacity (kVA)
0.9
1.4
2.6
3.7
4.2
5.5
7.0
11
14
specifi-
cations
Rated output
current (A)
1.2
1.8
3.4
4.8
5.5
7.2
9.2
14.8
18
Rated output
voltage (V)
3-phase 380 to 460 VAC (according to the input voltage)
Max. output
frequency
400 Hz parameter setting
Control
charac-
teristics
Harmonic-current
countermeasures
DC reactor (option) connection possible
charac-
teristics Control method
Sine wave PWM (V/f control)
Carrier frequency
2.5 to 10.0 kHz (in vector control)
Frequency control
range
0.1 to 400 Hz
Frequency
precision
(temperature
characteristics)
Digital commands:
±
0.01% (--10
°
C to 50
°
C)
Analog commands:
±
0.5% (25
°
C
±
10
°
C)
Frequency setting
resolution
Digital commands: 0.1 Hz (less than 100 Hz) and 1 Hz (100 Hz or
over)
Analog commands: 0.06 Hz/60 Hz (equivalent to 1/1000)
Output frequency
resolution
0.01 Hz
Overload capacity
150% of rated output current for 1 min
External frequency
set signal
Selectable with FREQ adjuster: 0 to 10 VDC (20 k
W
), 4 to 20 mA
(250
W
), and 0 to 20 mA (250
W
)
Acceleration/de-
celeration time
0.01 to 6,000 s (Independent acceleration and deceleration time
settings)
Braking torque
Approx. 20% (125 to 150% possible with braking resistor: 2 types)
Voltage/frequency
characteristics
Set voltage vector control/user V/f pattern
Specifications
Chapter 9
Содержание SYSDRIVE 3G3MV A2002
Страница 1: ...USER S MANUAL SYSDRIVE 3G3MV Multi function Compact Inverter Cat No I527 E2 02...
Страница 15: ...Chapter 1 Overview 1 1 Function 1 2 Nomenclature 1 3 New Features 1...
Страница 24: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Страница 69: ...Chapter 3 Preparing for Operation and Monitoring 3 1 Nomenclature 3 2 Parameter Copy and Verify Function 3...
Страница 89: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Страница 286: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9...
Страница 296: ...9 11 D 3G3MV PFI1040 E Three 5 dia holes Four M4 holes for Inverter mounting use Specifications Chapter 9...
Страница 298: ...9 13 D 3G3MV PFI2030 E Four M4 holes for Inverter mounting use Three 5 dia holes Specifications Chapter 9...
Страница 299: ...9 14 D 3G3MV PFI2050 E Four M5 holes for Inverter mounting use Three 6 dia holes Specifications Chapter 9...
Страница 301: ...9 16 D 3G3MV PRS3030V Four M5 holes for Inverter mounting use Three 6 dia holes Specifications Chapter 9...
Страница 311: ...Chapter 10 List of Parameters 10...
Страница 342: ...Chapter 11 Using the Inverter for a Motor 11...
Страница 348: ...Appendix A Standard Models...