5-28
n019
Acceleration Time 1
Register
0113
Hex
Changes during
operation
Yes
Setting
range
0.0 to 6,000 (s) (see note 1)
Unit of
setting
0.1 s
(see
note 1)
Default setting
10.0
n020
Deceleration Time 1
Register
0114
Hex
Changes during
operation
Yes
Setting
range
0.0 to 6,000 (s) (see note 1)
Unit of
setting
0.1 s
(see
note 1)
Default setting
10.0
n021
Acceleration Time 2
Register
0115
Hex
Changes during
operation
Yes
Setting
range
0.0 to 6,000 (s) (see note 1)
Unit of
setting
0.1 s
(see
note 1)
Default setting
10.0
n022
Deceleration Time 2
Register
0116
Hex
Changes during
operation
Yes
Setting
range
0.0 to 6,000 (s) (see note 1)
Unit of
setting
0.1 s
(see
note 1)
Default setting
10.0
Note 1.
The setting unit of acceleration or deceleration time is determined by the set
value in n018 (acceleration/deceleration time unit).
n018 set to 0: Setting range from 0.0 to 6,000 (0.0 through 999.9 s or 1,000
through 6,000 s)
n018 set to 1: Setting range from 0.00 to 600.0 (0.0 through 99.99 s or 100.0
through 600.0 s)
Note 2.
When n018 is set to 1, the default value of acceleration or deceleration time will
be set to 10.00.
H
S-shape Acceleration/Deceleration Characteristic (n023)
·
Trapezoidal and S-shape acceleration and deceleration are available. Using the
S-shape characteristic function for acceleration and deceleration can reduce shock to
the machinery when stopping or starting.
·
Any one of three S-shape acceleration/deceleration times (0.2, 0.5, and 1.0 s) is
selectable.
n023
S-shape Acceleration/
Deceleration Characteristic
Register
0117
Hex
Changes during
operation
No
Setting
range
0 to 3
Unit of
setting
1
Default setting
0
Basic Operation
Chapter 5
Содержание SYSDRIVE 3G3MV A2002
Страница 1: ...USER S MANUAL SYSDRIVE 3G3MV Multi function Compact Inverter Cat No I527 E2 02...
Страница 15: ...Chapter 1 Overview 1 1 Function 1 2 Nomenclature 1 3 New Features 1...
Страница 24: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Страница 69: ...Chapter 3 Preparing for Operation and Monitoring 3 1 Nomenclature 3 2 Parameter Copy and Verify Function 3...
Страница 89: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Страница 286: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9...
Страница 296: ...9 11 D 3G3MV PFI1040 E Three 5 dia holes Four M4 holes for Inverter mounting use Specifications Chapter 9...
Страница 298: ...9 13 D 3G3MV PFI2030 E Four M4 holes for Inverter mounting use Three 5 dia holes Specifications Chapter 9...
Страница 299: ...9 14 D 3G3MV PFI2050 E Four M5 holes for Inverter mounting use Three 6 dia holes Specifications Chapter 9...
Страница 301: ...9 16 D 3G3MV PRS3030V Four M5 holes for Inverter mounting use Three 6 dia holes Specifications Chapter 9...
Страница 311: ...Chapter 10 List of Parameters 10...
Страница 342: ...Chapter 11 Using the Inverter for a Motor 11...
Страница 348: ...Appendix A Standard Models...