6-39
6-9 Slip Compensation Function
The slip compensation function calculates the motor torque according to
the output current, and sets gain to compensate for output frequency.
This function is used to improve speed accuracy when operating with a
load. It is mainly valid for V/f gain.
n106
Rated Motor Slip
Register
016A
Hex
Changes during
operation
Yes
Setting
range
0.0 to 20.0 (Hz)
Unit of
setting
0.1 Hz
Default setting
(see
note)
Note
The default setting varies with the capacity of the Inverter model.
Set Values
·
Set the rated slip value of the motor in use.
·
This parameter is used as a slip compensation constant.
·
Calculate the rated motor slip value from the rated frequency (Hz) and rpm on the
motor nameplate by using the following formula.
Rated slit value (Hz)
=
Rated frequency (Hz) –
Rated rpm
×
Number of poles
120
n111
Slip Compensation Gain
Register
016F
Hex
Changes during
operation
Yes
Setting
range
0.0 to 2.5
Unit of
setting
0.1
Default setting
0.0
(see
note 1)
Note 1.
If set to vector control mode, the default value will be 1.0.
Note 2.
This parameter is disabled with the value set to 0.0.
Set Values
·
Set the parameter to 1.0 first and check the operation of the Inverter. Then fine-tune the
gain with 0.1-gain increments or decrements.
If the speed is lower than the target value, increase the set value.
If the speed is higher than the target value, decrease the set value.
n112
Slip Compensation Primary
Delay Time
Register
0170
Hex
Changes during
operation
No
Setting
range
0.0 to 25.5 (s)
Unit of
setting
0.1 s
Default setting
2.0
(see
note)
Advanced Operation
Chapter 6
Содержание SYSDRIVE 3G3MV A2002
Страница 1: ...USER S MANUAL SYSDRIVE 3G3MV Multi function Compact Inverter Cat No I527 E2 02...
Страница 15: ...Chapter 1 Overview 1 1 Function 1 2 Nomenclature 1 3 New Features 1...
Страница 24: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Страница 69: ...Chapter 3 Preparing for Operation and Monitoring 3 1 Nomenclature 3 2 Parameter Copy and Verify Function 3...
Страница 89: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Страница 286: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9...
Страница 296: ...9 11 D 3G3MV PFI1040 E Three 5 dia holes Four M4 holes for Inverter mounting use Specifications Chapter 9...
Страница 298: ...9 13 D 3G3MV PFI2030 E Four M4 holes for Inverter mounting use Three 5 dia holes Specifications Chapter 9...
Страница 299: ...9 14 D 3G3MV PFI2050 E Four M5 holes for Inverter mounting use Three 6 dia holes Specifications Chapter 9...
Страница 301: ...9 16 D 3G3MV PRS3030V Four M5 holes for Inverter mounting use Three 6 dia holes Specifications Chapter 9...
Страница 311: ...Chapter 10 List of Parameters 10...
Страница 342: ...Chapter 11 Using the Inverter for a Motor 11...
Страница 348: ...Appendix A Standard Models...