8-6
Fault
display
Probable cause and remedy
Fault name and
meaning
OL3
Overtorque detection
(OL3)
There has been a current
or torque the same as or
greater than the setting
in n098 for overtorque
detection level and that
in n099 for overtorque
detection time. A fault
has been detected with
n096 for overtorque
detection function
selection set to 2 or 4.
·
The mechanical system is locked or has a failure.
®
Check the mechanical system and correct the
cause of overtorque.
·
The parameter settings were incorrect.
®
Adjust the n098 and n099 parameters
according to the mechanical system.
Increase the set values in n098 and n099.
ef
j
External fault
j
(EF
j
)
An external fault has
been input from a
multi-function input.
A multi-function input 1 to
7 set to 3 or 4 has
operated. The EF
number indicates the
number of the
corresponding input (S1
to S7).
·
An external fault was input from a multi-function
input.
®
Remove the cause of the external fault.
·
The sequence is incorrect.
®
Check and change the external fault input
sequence including the input timing and NO or
NC contact.
f00
Digital Operator
transmission fault 1
(F00)
No communications were
possible with the Digital
Operator for 5 s or more
after the Inverter had
been turned ON.
·
The Digital Operator may not be mounted prop-
erly.
®
Turn OFF the Inverter, dismount and mount the
Digital Operator, and turn ON the Inverter.
·
The Digital Operator has a failure.
®
Change the Digital Operator.
·
The Inverter has a failure.
®
Change the Inverter.
f01
Digital Operator
transmission fault 2
(F01)
A transmission fault
continued for 5 s or more
after communications
with the Digital Operator
had failed.
·
The Digital Operator may not be mounted prop-
erly.
®
Turn OFF the Inverter, dismount and mount the
Digital Operator, and turn ON the Inverter.
·
The Digital Operator has a failure.
®
Change the Digital Operator.
·
The Inverter has a failure.
®
Change the Inverter.
Maintenance Operations
Chapter 8
Содержание SYSDRIVE 3G3MV A2002
Страница 1: ...USER S MANUAL SYSDRIVE 3G3MV Multi function Compact Inverter Cat No I527 E2 02...
Страница 15: ...Chapter 1 Overview 1 1 Function 1 2 Nomenclature 1 3 New Features 1...
Страница 24: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Страница 69: ...Chapter 3 Preparing for Operation and Monitoring 3 1 Nomenclature 3 2 Parameter Copy and Verify Function 3...
Страница 89: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Страница 286: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9...
Страница 296: ...9 11 D 3G3MV PFI1040 E Three 5 dia holes Four M4 holes for Inverter mounting use Specifications Chapter 9...
Страница 298: ...9 13 D 3G3MV PFI2030 E Four M4 holes for Inverter mounting use Three 5 dia holes Specifications Chapter 9...
Страница 299: ...9 14 D 3G3MV PFI2050 E Four M5 holes for Inverter mounting use Three 6 dia holes Specifications Chapter 9...
Страница 301: ...9 16 D 3G3MV PRS3030V Four M5 holes for Inverter mounting use Three 6 dia holes Specifications Chapter 9...
Страница 311: ...Chapter 10 List of Parameters 10...
Страница 342: ...Chapter 11 Using the Inverter for a Motor 11...
Страница 348: ...Appendix A Standard Models...