5-4
V/f Control Mode
This mode, which is used by conventional general-purpose inverters, is convenient
when replacing a conventional model with the 3G3MV Inverter because the Inverter in
this mode can be operated without considering the constants of the motor. Furthermore,
set the Inverter to this mode if the Inverter is connected to more than one motor or spe-
cial motors such as high-speed motors.
n002
Control Mode Selection
Register
0102
Hex
Changes during
operation
No
Setting
range
0, 1
Unit of
setting
1
Default setting
0
Note
This parameter is used for selecting the control mode of the Inverter.
Set Values
Value
Description
0
V/f control mode
1
Vector control mode (open loop)
Note 1.
This parameter is not initialized by setting n001 (parameter write-prohibit selec-
tion/parameter initialization) to 8 or 9 for parameter initialization.
Note 2.
Each of the following parameters is initialized according to the control mode set
in this parameter. The default value varies with the control mode. Therefore, be
sure to set the following parameters after setting the control mode in n002.
Parame-
ter
Name
Default value
Parame-
ter
Name
V/f control
(Set value: 0)
Vector control
(Set value: 1)
n014
Middle output frequency
1.5 Hz
3.0 Hz
n015
Middle output frequency
voltage
12.0 V (24.0 V)
(see note 2)
11.0 V (22.0 V)
n016
Minimum output frequency
1.5 Hz
1.0 Hz
n017
Minimum output frequency
voltage
12.0 V (24.0 V)
(see note 2)
4.3 V (8.6 V)
n104
Torque compensation
primary-delay time constant
0.3 s
0.2 s
n111
Slip compensation gain
0.0
1.0
n112
Slip compensation
primary-delay time constant
2.0 s
0.2 s
Note 1.
Values in parentheses are for 400-V models.
Note 2.
For 5.5- and 7.5-kW Inverters, this value is set to 10.0 V for 200-V-class models
and to 20.0 V for 400-V-class models.
Basic Operation
Chapter 5
Содержание SYSDRIVE 3G3MV A2002
Страница 1: ...USER S MANUAL SYSDRIVE 3G3MV Multi function Compact Inverter Cat No I527 E2 02...
Страница 15: ...Chapter 1 Overview 1 1 Function 1 2 Nomenclature 1 3 New Features 1...
Страница 24: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Страница 69: ...Chapter 3 Preparing for Operation and Monitoring 3 1 Nomenclature 3 2 Parameter Copy and Verify Function 3...
Страница 89: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Страница 286: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9...
Страница 296: ...9 11 D 3G3MV PFI1040 E Three 5 dia holes Four M4 holes for Inverter mounting use Specifications Chapter 9...
Страница 298: ...9 13 D 3G3MV PFI2030 E Four M4 holes for Inverter mounting use Three 5 dia holes Specifications Chapter 9...
Страница 299: ...9 14 D 3G3MV PFI2050 E Four M5 holes for Inverter mounting use Three 6 dia holes Specifications Chapter 9...
Страница 301: ...9 16 D 3G3MV PRS3030V Four M5 holes for Inverter mounting use Three 6 dia holes Specifications Chapter 9...
Страница 311: ...Chapter 10 List of Parameters 10...
Страница 342: ...Chapter 11 Using the Inverter for a Motor 11...
Страница 348: ...Appendix A Standard Models...