3-16
If a set range error results, the corresponding parameter number will flash. In
the case of a verification error, “oP
j
” (
j
is a figure) will flash.
Note 2.
The following parameter set values or output frequency on hold cannot be
copied.
n176: Parameter copy function selection
n178: Error log
n177: Parameter read-prohibit selection
n179: Software version
Note 3.
The following parameter set values cannot be copied if the Inverters are differ-
ent to each other in capacity.
n011 to n017: V/f setting
n108: Motor leakage inductance
n036: Rated motor current
n109: Torque compensation limit
n080: Carrier frequency
n110: Motor no-load current
n105: Torque compensation core loss n140: Energy-saving control coefficient K2
n106: Rated motor slip
n158: Motor code
n107: Motor wire-to-wire resistance
Note 4.
Functions for 5.5/7.5kW Inverters cannot be copied to Inverters with different
capacities.
H
Verifying the Parameter Set Values (vFy)
·
In order to verify that the copied parameter set values in the Inverter coincide with
those in the EEPROM of the Digital Operator, set n176 for parameter copy function
selection to vFy.
Note
The parameter set values can be verified provided that they are copied between
the Inverters that are the same in power supply specification and control mode
(i.e., V/f or vector control).
D
Procedure to Verify the Parameter Set Values
Key
sequence
Indicator
Display
example
Explanation
Power ON
Press the Mode Key repeatedly until the
PRGM indicator is lit.
Use the Increment or Decrement Key to
display “n176.”
Press the Enter Key. Then “rdy” will be
displayed.
Use the Increment Key to display “vFy.”
Press the Enter Key so that the parameter
set values are verified, during which the
display flashes.
Preparing for Operation and Monitoring
Chapter 3
Содержание SYSDRIVE 3G3MV A2002
Страница 1: ...USER S MANUAL SYSDRIVE 3G3MV Multi function Compact Inverter Cat No I527 E2 02...
Страница 15: ...Chapter 1 Overview 1 1 Function 1 2 Nomenclature 1 3 New Features 1...
Страница 24: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Страница 69: ...Chapter 3 Preparing for Operation and Monitoring 3 1 Nomenclature 3 2 Parameter Copy and Verify Function 3...
Страница 89: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Страница 286: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9...
Страница 296: ...9 11 D 3G3MV PFI1040 E Three 5 dia holes Four M4 holes for Inverter mounting use Specifications Chapter 9...
Страница 298: ...9 13 D 3G3MV PFI2030 E Four M4 holes for Inverter mounting use Three 5 dia holes Specifications Chapter 9...
Страница 299: ...9 14 D 3G3MV PFI2050 E Four M5 holes for Inverter mounting use Three 6 dia holes Specifications Chapter 9...
Страница 301: ...9 16 D 3G3MV PRS3030V Four M5 holes for Inverter mounting use Three 6 dia holes Specifications Chapter 9...
Страница 311: ...Chapter 10 List of Parameters 10...
Страница 342: ...Chapter 11 Using the Inverter for a Motor 11...
Страница 348: ...Appendix A Standard Models...