A Appendix
A - 72
GX-series EtherCAT Slave Unit User’s Manual
*1 Indexes 9011 hex, 9021 hex, 9031 hex, 9041 hex, 9051 hex, and 9061 hex are intentionally omitted from this
table. Port numbers in each object name of the indexes 9001 hex to 9061 hex are assigned in order from port 2
to port 7, in ascending order. The data definitions, except for the object names, are the same as those for
indexes 9001 hex and 9071 hex.
*1 Supported by the unit version 1.1 or later.
*2 Indexes 9012 hex, 9022 hex, 9032 hex, 9042 hex, 9052 hex, and 9062 hex are intentionally omitted from this
table. Port numbers in each object name of the indexes 9002 hex to 9062 hex are assigned in order from port 2
to port 7, in ascending order. The data definitions, except for the object names, are the same as those for
indexes 9002 hex and 9072 hex.
*1 Supported by the unit version 1.1 or later.
*2 Indexes 9013 hex, 9023 hex, 9033 hex, 9043 hex, 9053 hex, and 9063 hex are intentionally omitted from this
table. Port numbers in each object name of the indexes 9003 hex to 9063 hex are assigned in order from port 2
to port 7, in ascending order. The data definitions, except for the object names, are the same as those for
indexes 9003 hex and 9073 hex.
9001 hex
Port1 Serial Number Information Area
Range: -
Unit: -
Default: -
Attribute: -
Size: 16 bytes (VS)
Access: RO
PDO map: Not possible
· · ·
*1
9071 hex
Port8 Serial Number Information Area
Range: -
Unit: -
Default: -
Attribute: -
Size: 16 bytes (VS)
Access: RO
PDO map: Not possible
9002 hex
*1
Port1 Vendor Name
Range: -
Unit: -
Default: -
Attribute: -
Size: 64 bytes (VS)
Access: RO
PDO map: Not possible
· · ·
*2
9071 hex
*1
Port8 Vendor Name
Range: -
Unit: -
Default: -
Attribute: -
Size: 16 bytes (VS)
Access: RO
PDO map: Not possible
9003 hex
*1
Port1 Product Name
Range: -
Unit: -
Default: -
Attribute: -
Size: 64 bytes (VS)
Access: RO
PDO map: Not possible
· · ·
*2
9073 hex
*1
Port8 Product Name
Range: -
Unit: -
Default: -
Attribute: -
Size: 64 bytes (VS)
Access: RO
PDO map: Not possible
A000 hex
Port1 IO-Link Master Object
Sub-index 0: Number of entries
Range:
−
Unit:
−
Default: 01 hex
Attribute:
−
Size: 1 byte (U8)
Access: RO
PDO map: Not possible
Sub-index 1: Port1 Lost Frames
Range: 00 to FF hex
Unit:
−
Default: 00 hex
Attribute: A
Size: 1 byte (U8)
Access: RW
PDO map: Not possible
A010 hex
Port2 IO-Link Master Object
Sub-index 0: Number of entries
Range:
−
Unit:
−
Default: 01 hex
Attribute:
−
Size: 1 byte (U8)
Access: RO
PDO map: Not possible
Sub-index 1: Port2 Lost Frames
Range: 00 to FF hex
Unit:
−
Default: 00 hex
Attribute: A
Size: 1 byte (U8)
Access: RW
PDO map: Not possible
Содержание GX-AD0471
Страница 3: ...GX series EtherCAT Slave Units User s Manual Revised October 2018...
Страница 4: ......
Страница 34: ...1 EtherCAT Network 1 8 GX series EtherCAT Slave Unit User s Manual Separate from Unit power supply when wiring...
Страница 42: ...2 EtherCAT Slave Unit 2 8 GX series EtherCAT Slave Unit User s Manual...
Страница 66: ...4 Installation and Wiring 4 18 GX series EtherCAT Slave Unit User s Manual...
Страница 84: ...5 EtherCAT Communications 5 18 GX series EtherCAT Slave Unit User s Manual...
Страница 98: ...6 Basic Specifications of Slave Units 6 14 GX series EtherCAT Slave Unit User s Manual...
Страница 178: ...7 Digital I O Slave Unit 7 80 GX series EtherCAT Slave Unit User s Manual...
Страница 206: ...8 Analog I O Slave Unit 8 28 GX series EtherCAT Slave Unit User s Manual...
Страница 280: ...11 Expansion Unit 11 20 GX series EtherCAT Slave Unit User s Manual...
Страница 388: ...A Appendix A 84 GX series EtherCAT Slave Unit User s Manual...
Страница 392: ...Revision 2 GX series EtherCAT Slave Unit User s Manual...
Страница 393: ......