A Appendix
A - 54
GX-series EtherCAT Slave Unit User’s Manual
Manufacturer-specific Area 2
The following table shows the bit configuration of the I/O Port Status object. The status can be
accessed either as WORD data or BOOL data.
The contents of
Error Status for Ports 1 and 2
are given below. The status can be accessed either as
WORD data or BOOL data.
IO-Link Master Unit
3000 hex
I/O Port Status
Sub-index 0: Number of entries
Range:
−
Unit:
−
Default: 01 hex
Attribute:
−
Size: 1 byte (U8)
Access: RO
PDO map: Not possible
Sub-index 1: I/O Port Status
Range:
−
Unit:
−
Default: 0000 hex
Attribute:
−
Size: 2 bytes (U16)
Access: RO
PDO map: Not possible
3001 hex
Port1_2 I/O Port Error Status
Sub-index 0: Number of entries
Range:
−
Unit:
−
Default: 01 hex
Attribute:
−
Size: 1 byte (U8)
Access: RO
PDO map: Not possible
Sub-index 1: Port1_2 I/O Port Error Status
Range:
−
Unit:
−
Default: 0000 hex
Attribute:
−
Size: 2 bytes (U16)
Access: RO
PDO map: Not possible
Bit
Meaning
Default
value
Data range
Unit
Data type
Access
I/O allo-
cation
Data
attribute
0
Port 1 Input Data Enabled Flag
FALSE
FALSE/TRUE
---
BOOL
RO
Possible
---
1
Port 2 Input Data Enabled Flag
FALSE
FALSE/TRUE
---
BOOL
RO
Possible
---
2
Port 3 Input Data Enabled Flag
FALSE
FALSE/TRUE
---
BOOL
RO
Possible
---
3
Port 4 Input Data Enabled Flag
FALSE
FALSE/TRUE
---
BOOL
RO
Possible
---
14
IO-Link Communications Module
Processing Error
FALSE
FALSE/TRUE
---
BOOL
RO
Possible
---
15
I/O Power On/Off Status
FALSE
FALSE/TRUE
---
BOOL
RO
Possible
---
Bit
Meaning
Default
value
Data range
Unit
Data type
Access
I/O allo-
cation
Data
attribute
0
Port 1 IO-Link Communications
Error Flag
FALSE
FALSE/TRUE
---
BOOL
RO
Possible
---
1
Port 1 I/O Short Detected Flag
FALSE
FALSE/TRUE
---
BOOL
RO
Possible
---
2
Port 1 Verification Error Flag
FALSE
FALSE/TRUE
---
BOOL
RO
Possible
---
3
Port 1 Device I/O Size Error Flag
FALSE
FALSE/TRUE
---
BOOL
RO
Possible
---
4
Port 1 Device Error-level Event
Flag
FALSE
FALSE/TRUE
---
BOOL
RO
Possible
---
5
Port 1 Device Warning-level Event
Flag
FALSE
FALSE/TRUE
---
BOOL
RO
Possible
---
6
Port 1 PDO Mapping Error Flag
FALSE
FALSE/TRUE
---
BOOL
RO
Possible
---
8
Port 2 IO-Link Communications
Error Flag
FALSE
FALSE/TRUE
---
BOOL
RO
Possible
---
9
Port 2 IO Short Detected Flag
FALSE
FALSE/TRUE
---
BOOL
RO
Possible
---
10
Port 2 Verification Error Flag
FALSE
FALSE/TRUE
---
BOOL
RO
Possible
---
11
Port 2 Device I/O Size Error Flag
FALSE
FALSE/TRUE
---
BOOL
RO
Possible
---
12
Port 2 Device Error-level Event
Flag
FALSE
FALSE/TRUE
---
BOOL
RO
Possible
---
13
Port 2 Device Warning-level Event
Flag
FALSE
FALSE/TRUE
---
BOOL
RO
Possible
---
14
Port 2 PDO Mapping Error Flag
FALSE
FALSE/TRUE
---
BOOL
RO
Possible
---
Содержание GX-AD0471
Страница 3: ...GX series EtherCAT Slave Units User s Manual Revised October 2018...
Страница 4: ......
Страница 34: ...1 EtherCAT Network 1 8 GX series EtherCAT Slave Unit User s Manual Separate from Unit power supply when wiring...
Страница 42: ...2 EtherCAT Slave Unit 2 8 GX series EtherCAT Slave Unit User s Manual...
Страница 66: ...4 Installation and Wiring 4 18 GX series EtherCAT Slave Unit User s Manual...
Страница 84: ...5 EtherCAT Communications 5 18 GX series EtherCAT Slave Unit User s Manual...
Страница 98: ...6 Basic Specifications of Slave Units 6 14 GX series EtherCAT Slave Unit User s Manual...
Страница 178: ...7 Digital I O Slave Unit 7 80 GX series EtherCAT Slave Unit User s Manual...
Страница 206: ...8 Analog I O Slave Unit 8 28 GX series EtherCAT Slave Unit User s Manual...
Страница 280: ...11 Expansion Unit 11 20 GX series EtherCAT Slave Unit User s Manual...
Страница 388: ...A Appendix A 84 GX series EtherCAT Slave Unit User s Manual...
Страница 392: ...Revision 2 GX series EtherCAT Slave Unit User s Manual...
Страница 393: ......