A Appendix
A - 32
GX-series EtherCAT Slave Unit User’s Manual
This section explains the CiA401 generic I/O module device profile implemented in GX-series
EtherCAT Slave Units and the objects specially mounted in GX-series EtherCAT Slave Units.
Manufacturer Specific area 1
•
This object clears diagnosis history of 10F3 hex (Diagnosis History).
•
It clears the history only when specific values are written. The specific value is "elcl".
Writing values other than this is invalid.
•
The mapping is used for Sysmac error status notification and to clear Sysmac error status.
•
Sub-index 1: Sysmac Error Status
•
This object is for notification of errors that are detected in the Slave Unit.
•
When connected to an NJ-series Machine Automation Controller (NJ501-1
@
00), map this object
to a PDO.
•
Sub-index 2: Sysmac Error Status Clear
•
This object is used by the Controller (a Sysmac device) to reset errors that occur in Slave Units.
•
For the GX-series Digital I/O Slave Units, Analog I/O Slave Units, and Encoder Input Slave Units, this
object can be set for unit version 1.1 or later.
•
For the GX-series IO-Link Master Unit, this object can be set for unit version 1.0 or later.
Reference
In the default Sysmac Studio settings, sub-index 1 (Sysmac Error Status) is automatically
mapped to a PDO because 1BFF hex (512th transmit PDO Mapping) is assigned.
A-1-7
Manufacturer Specific Objects
All Slave Units
2100 hex
Error History Clear
Range:
−
Unit:
−
Default: 00000000 hex
Attribute: A
Size: 4 bytes (U32)
Access: RW
PDO map: Not possible
MSB
LSB
l
c
l
e
6C hex
63 hex
6C hex
65 hex
2002 hex
Sysmac Error
Sub-index 0: Number of entries
Range:
−
Unit:
−
Default: 02 hex
Attribute:
−
Size: 1 byte (U8)
Access: RO
PDO map: Not possible
Sub-index 1: Sysmac Error Status
Range:
−
Unit:
−
Default: 00 hex
Attribute:
−
Size: 1 byte (U8)
Access: RO
PDO map: Possible
Sub-index 2: Sysmac Error Status Clear
Range:
−
Unit:
−
Default: 00 hex
Attribute: A
Size: 1 byte (U8)
Access: RW
PDO map: Not possible
Содержание GX-AD0471
Страница 3: ...GX series EtherCAT Slave Units User s Manual Revised October 2018...
Страница 4: ......
Страница 34: ...1 EtherCAT Network 1 8 GX series EtherCAT Slave Unit User s Manual Separate from Unit power supply when wiring...
Страница 42: ...2 EtherCAT Slave Unit 2 8 GX series EtherCAT Slave Unit User s Manual...
Страница 66: ...4 Installation and Wiring 4 18 GX series EtherCAT Slave Unit User s Manual...
Страница 84: ...5 EtherCAT Communications 5 18 GX series EtherCAT Slave Unit User s Manual...
Страница 98: ...6 Basic Specifications of Slave Units 6 14 GX series EtherCAT Slave Unit User s Manual...
Страница 178: ...7 Digital I O Slave Unit 7 80 GX series EtherCAT Slave Unit User s Manual...
Страница 206: ...8 Analog I O Slave Unit 8 28 GX series EtherCAT Slave Unit User s Manual...
Страница 280: ...11 Expansion Unit 11 20 GX series EtherCAT Slave Unit User s Manual...
Страница 388: ...A Appendix A 84 GX series EtherCAT Slave Unit User s Manual...
Страница 392: ...Revision 2 GX series EtherCAT Slave Unit User s Manual...
Страница 393: ......