EX Series Operating Manual
▌Enters a voltage value that you obtained by reading an external DVM
meter. If the value is 31.618+I3478mV, enters as following below.
This is an examples for 30
LCD Display
V-high 31.61v
Voltage output power supply.
LCD Display
V high 31.61v
Voltage output power supply.
▌After finished to enter the value, press the "Calibration" key.
LCD Display
ADC datA f100h
During around 500ms, display
HEX value instead of readback value
LCD Display
2.cal-volt high
Return to before state of Mcalibrating.
▌It is finish of voltage calibration. You can use the power supply
next time by applying this data.
Current Calibration
Current Calibration
▌Turn off all device and connect all device before calibration.
>When current calibration, connect the power supply (+) output terminal and electronic load
and connect the power supply (-) output terminal and shunt lead for current monitoring
and then connect shunt's the other lead to electronic load (-) terminal
>Connect the DVM (+) test lead at the electronic load connction of current monitoring resistor
>Connect the DVM (+) test lead at the electronic load connction of current monitoring resistor
connect the DVM (-) test lead at the other side of current monitoring resistor.
▌Power switch on in a pressing calibration key.
▌Power switch on.
In a pressing
▌After finished self test, when appearing "1.cal-volt low" message,
release calibration key.
▌Move to "3.cal-curr low" mode by using cursor key and press
the "Calibration" key.
Release
LCD Display
a-LOW 00.14a
It is able to differ about volt display.
▌Wait until DVM display voltage becomes stable.
Wait for 5 minute.
- 70 -
Содержание EX Series
Страница 2: ......
Страница 104: ...EX Series Operating Manual 104...
Страница 105: ...EX Series Operating Manual 105...
Страница 107: ...EX Series Operating Manual 2U 2 6KW 5KW Product Outside Dimension 2U 2 6KW 5KW Product Rear Feature 107...
Страница 108: ...EX Series Operating Manual 4U 5 1KW 10KW Product Outside Dimension 4U 5 1KW 10KW Product Rear Feature 108...
Страница 113: ...EX Series Operating Manual Reliability Durability Life time Test System Solution 113...