EX Series Operating Manual
3-7. Programming Under Current Limit(UCL)
Normally, you can adjust the current from 0V to maximum current but if you set the UCL level,
you can adjust the current from UCL level to maximum current.
▌Turn on the power supply
After turned on, check the power supply displays"
**OUTPUT OFF**
" Mode.
▌Before setting the UCL level, current limit setting value must be higher
than UCL level. And then you can set the UCL limit value.
▌In other to set the current, move the under bar cursor where you want
by using right cursor key and set the current by using encoder knob.
Under the protection(OVP/UVL/OVL) setting state, current cannot be over the
on the display and current value returns to protection level value
protection level. If the level over, "
PROTECTION LIMIT
" message appears
on the display and current value returns to protection level value.
▌Press the "Protection" key in other to set the UCL level.
LCD Display
PROTECT> 1.OVP
▌Move to the CVL menu by using right cursor key.
LCD Display
PROTECT> 5.ucl
LCD Display
PROTECT> 5.ucl
▌Press the "Protection" key one more time at the "5. ucl" state.
LCD Display
UCL SET> 00.00A
▌Move the under bar cursor location where you want to change.
▌Set the Under Current Level by using encoder knob
▌Set the Under Current Level by using encoder knob.
Note that you cannot set the limit levels to lower than current real output
current in other to prevent the operator's malfunction occurring.
▌After set the limit levels that you want, press the "Protection" Key.
LCD Display
CHANGED
After displayed above message, The power supply will exit the UCL
menu and the display will return to the meter mode
menu and the display will return to the meter mode.
Cancelling
▌If you don't want to change the UVL levels, just wait during 5 seconds.
Wait 5 sec
LCD Display
CANCEL…
≫ Related Remote Interface Command
CURR:UCL {<current>}
CURR:UCL?
Apply :
CURR:UCL 5
Set the UCL level.
About initial OCL setting, refer to Default Setting Values of "1-6. Check After Power On"
Note
- 35 -
Содержание EX Series
Страница 2: ......
Страница 104: ...EX Series Operating Manual 104...
Страница 105: ...EX Series Operating Manual 105...
Страница 107: ...EX Series Operating Manual 2U 2 6KW 5KW Product Outside Dimension 2U 2 6KW 5KW Product Rear Feature 107...
Страница 108: ...EX Series Operating Manual 4U 5 1KW 10KW Product Outside Dimension 4U 5 1KW 10KW Product Rear Feature 108...
Страница 113: ...EX Series Operating Manual Reliability Durability Life time Test System Solution 113...