EX Series Operating Manual
CURR?
This query returns the presently programmed current level of the power supply.
RetReturn value "current"
ex) curr?
return value "4.50"
CURR:STEP {<numeric value>}
This command sets the step size for current programming with the CURRent UP and
This command sets the step size for current programming with the CURRent UP and
CURRent DOWN commands.
> numeric value
Program the power supply to the allowed setting value resolution.
ex) curr:step 0.5
Set the voltage to 0.5A .
CURR:STEP?
This query returns the value of the step size currently specified. The returned parameter is a
This query returns the value of the step size currently specified. The returned parameter is a
numeric value.
Return value "numeric value"
ex) curr:step?
return value "0.50"
CURR:OCP {<numeric value>}
This command sets the current level at which the overcurrrent protection circuit will trip.
> numeric value
Input current within OVP setting range
> numeric value
Input current within OVP setting range.
ex) curr:ocp 5.2
Set the OVP Level to 5.2A
CURR:OCP?
This query returns the overcurrent protection trip level presently programmed.
Return value "numeric value"
)
:
?
t
l
"5 20"
ex) curr:ocp?
return value "5.20"
CURR:OCP:TRIP?
This query returns a ‘‘1’’ if the overcurrent protection circuit is tripped and not cleared or
a ‘‘0’’ if not tripped.
Return value
"0" - not tripped state.
"1" - OCP Trip state and cut the output.
ex) curr:ocp:trip?
return value "1"
CURR:OCP:CLE
This command causes the overcurrent protection circuit to be cleared
Before release trip, refer to "3-4. Programming Over Current Protection(OVP)" in other to check
the reason of trip occuring and remove this reason.
)
:
: l
Cl
th OCP T i
ex) curr:ocp:cle
Clear the OCP Trip.
When appears OCP Trip, cut the voltage/current output. At that time, if you set
the voltage/current, it can be set. But DC output is still cut unless release the trip mode.
Note
- 89 -
Содержание EX Series
Страница 2: ......
Страница 104: ...EX Series Operating Manual 104...
Страница 105: ...EX Series Operating Manual 105...
Страница 107: ...EX Series Operating Manual 2U 2 6KW 5KW Product Outside Dimension 2U 2 6KW 5KW Product Rear Feature 107...
Страница 108: ...EX Series Operating Manual 4U 5 1KW 10KW Product Outside Dimension 4U 5 1KW 10KW Product Rear Feature 108...
Страница 113: ...EX Series Operating Manual Reliability Durability Life time Test System Solution 113...