EX Series Operating Manual
1-6. Check After Power On.
The power-on test includes an automatic self-test that checks the internal microprocessors
and allows the user visually to check the display. You will observe the following sequence
on the display after pressing the front panel power switch to on. And also keep the
ex-remote and voltage value is zero and current value is max value.OVP & OCP level are
g
set to maximum output value of instrument capacity and it is under the vigilance.
Display Procedure on the LCD
▌
Display
"
ODA Technologies
".
▌
Display
"
EX-Series Ver1.3
"의 제품명이 Display됩니다.
▌Annunciators of ERR,LMT,RMT,LOCK on front side are lit and go off clockwise from
th l ft
the left.
CV & CC annunciators are not applied.
▌During displaying above procedure, the instrument is initialized by stored in non-
volatile memory.
▌Also the instrument runs automatic self-test below mentioned.
Connection test between front panel and connector.
Remote interface test
Check remote interface for PC communication.
Front panel test
Remote interface test
Check remote interface for PC communication.
Memory data confirm test
Check product information and related setting.
ADC H/W error test
Check error on ADC control condition.
Unregulated state test
Check output voltage floating state.
ADC/DAC calibration test
check ADC & DAC Calibration data state.
If the error occurs, alarm beeps and the error code is saved to volatile memory
automatically. You can read the error code by pressing error key.
About error code explanation, refer to “7. Error Messages”.
About error code explanation, refer to 7. Error Messages .
Default Setting Values
(Last state Mode is under the Disable state)
▌OVP : OVP value is max, state is ON.
▌Remote Interface : RS-232C
▌OCP : OCP value is max, state is ON.
▌State after self-test : "**OUTPUT OFF**"
▌UVL : 0V
▌Cursor location : Default voltage select
▌OVL : Limit setting maximum value.
Voltage : 1V
▌UCL : 0A
Current : 100mA if current is under 5A.
▌OCL
Li i
i
i
l
I
f
d
0A
1A
▌OCL : Limit setting maximum value.
In case of under 50A : 1A
▌Output Voltage : 0V
In case of under 100A : 10A
▌Output Current : Limit setting maximum value.
▌KEY LOCK : OFF
Remote Interface default is RS232C and the rate is set to 9600 baud when the power supply is
shipped from the factory. TCP/IP Module is optional and bulit in type.When ordering, please request.
Note1
In case of "Last State", it is disable when the power supply is shipped from the factory. If you want to
use this function, it is able to use in "Factory Mode". Refer to "5-4. Last State"
If attached the option of remote analog controll board, output is set by setting value.
Note2
Note3
- 15 -
Содержание EX Series
Страница 2: ......
Страница 104: ...EX Series Operating Manual 104...
Страница 105: ...EX Series Operating Manual 105...
Страница 107: ...EX Series Operating Manual 2U 2 6KW 5KW Product Outside Dimension 2U 2 6KW 5KW Product Rear Feature 107...
Страница 108: ...EX Series Operating Manual 4U 5 1KW 10KW Product Outside Dimension 4U 5 1KW 10KW Product Rear Feature 108...
Страница 113: ...EX Series Operating Manual Reliability Durability Life time Test System Solution 113...