3-1. Constant Voltage Operating(CV)
To set up the power supply for constant voltage (CV) operation, proceed as follows.
(This operating is the examples that the function of "Last State Mode" is disable.)
▌Turn on the power supply
After turned on, check the power supply displays"
**OUTPUT OFF**
" Mode.
,
p
pp y
p y
▌Connect the DUT to output terminals.
▌In other to set the limit value, press the LMT Key.
▌Press the left key and move the under bar cursor to voltage value. In other to
increase or decrease the voltage value, turn the encoder switch CW or CCW.
Under the protection(OVP/UVL/OVL) setting state voltage cannot be over
Under the protection(OVP/UVL/OVL) setting state, voltage cannot be over
protection level. If the voltage value is over the protection setting value,
instrument "displays "PROTECTION LIMIT" message and voltage will set to
protection level value.
▌If you set the current value higher than DUT consumes real value, you can
prevent to damage the DUT. Refer to below procedure of current setting.
▌In other to set the current value, use the right cursor key and encoder knob.
Under the protection(OVP/UVL/OVL) setting state, current cannot be over
protection level. If the voltage value is over the protection setting value,
instrument "displays "PROTECTION LIMIT" message and current will set to
protection level value.
▌If the all setting is finished, enable the output.(Press the output ON/OFF key)
d h
l
h
db
k di
l
f
li i di
l
and then power supply changes to readback display from limit display.
▌CV lamp is on, CC lamp is off.
If lamp is reversed, check the current setting value is low.
If the current value is low, increase the current value limit.
≫ Related remote interface command
APPLy{<voltage>,<current>}
APPLy{<voltage>,<current>}
VOLT{<voltage>|UP|DOWN}
CURR{<current>|UP|DOWN}
OUTP{OFF|ON}
Apply 1
OUTP OFF
disable the output
Apply 2
OUTP OFF
disable the output
VOLT 10
set the voltage to 10V
APPLY 10,5
set 0V /5A
CURR 5
set the current to 5A
OUTP ON
enable the output
OUTP ON
enable the output
OUTP ON
enable the output
1. Left cursor key is for voltage under bar left moving, right cursor key is for current under
bar right moving.
2. About readback Display? Display state that is the voltage and current,s output.
Note
- 26 -
Содержание EX Series
Страница 2: ......
Страница 104: ...EX Series Operating Manual 104...
Страница 105: ...EX Series Operating Manual 105...
Страница 107: ...EX Series Operating Manual 2U 2 6KW 5KW Product Outside Dimension 2U 2 6KW 5KW Product Rear Feature 107...
Страница 108: ...EX Series Operating Manual 4U 5 1KW 10KW Product Outside Dimension 4U 5 1KW 10KW Product Rear Feature 108...
Страница 113: ...EX Series Operating Manual Reliability Durability Life time Test System Solution 113...