EX Series Operating Manual
7-5. Measure Commands
Measure commands measure the output voltage or current. MEASure commands acquire new
data before returning the reading. Also you don't need DVM(Digital Volt Meter) and ammeter
and you can measure voltage and current independently.
MEAS:VOLT?
These queries perform a measurement and return the DC output voltage in volts.
These queries perform a measurement and return the DC output voltage in volts.
Return value "voltage"
ex) meas:volt?
return value "11.00"
MEAS:CURR?
These queries perform a measurement and return the DC output current in amperes.
Return value "current"
)
:
?
t
l
"1 00"
ex) meas:curr?
return value "1.00"
MEAS:ALL?
These queries perform a measurement and return the DC output current in amperes and
DC output voltage in volts.
Return value "voltage,current"
ex) meas:all?
return value "10.00,1.00" // measured value of 10V, 1A.
7-6. Remote Connector Commands
This commands, at the located on rear panel, is the control command of analog control
connector. Also you can use it when you order option of analog control.
REM:VPROG {LOC|REM}
This command is the choosing the state between controlling under local mode and remote mode.
This command is the choosing the state between controlling under local mode and remote mode.
> LOC
Local mode controlling. You must choose it when you control P/S by RS232 or etc.
> REM
Remote mode controlling.You can't control P/S by communication commands.
Thi ex) Rem:VProg LOC
You can choose the local mode.
REM:VPROG?
This command is the checking the state of voltage programming between local and remote.
Return value
"LOC"
Current state is local mode.
Return value
LOC
Current state is local mode.
"REM"
Current state is remote mode.
ex)Rem:VProg?
return value "LOC"
REM:IPROG {LOC|REM}
This command is the choosing the state between controlling under local mode and remote mode.
> LOC
Local mode controlling. You must choose it when you control P/S by RS232 or etc.
> REM
Remote mode controlling.You can't control P/S by communication commands.
> REM
Remote mode controlling.You can t control P/S by communication commands.
ex) Rem:IProg LOC
You can choose the local mode.
REM:IPROG?
This command is the checking the state of current programming between local and remote.
Return value
"LOC"
Current state is local mode.
"REM"
Current state is remote mode.
)R
:IP
?
t
l
"LOC"
ex)Rem:IProg?
return value "LOC"
- 91 -
Содержание EX Series
Страница 2: ......
Страница 104: ...EX Series Operating Manual 104...
Страница 105: ...EX Series Operating Manual 105...
Страница 107: ...EX Series Operating Manual 2U 2 6KW 5KW Product Outside Dimension 2U 2 6KW 5KW Product Rear Feature 107...
Страница 108: ...EX Series Operating Manual 4U 5 1KW 10KW Product Outside Dimension 4U 5 1KW 10KW Product Rear Feature 108...
Страница 113: ...EX Series Operating Manual Reliability Durability Life time Test System Solution 113...