9. Details of Command and Parameter
— 9-59 —
RL
: Read LOS Counter
This monitor reports the state of the resolver wire disconnection counter.
Category
monitor
Format
RL
Data range
0 to 31
The monitor RL is used to distinguish whether the resolver wire is completely broken or broken for a
moment when the alarm A0 (Position sensor error) occurs.
P
RP : Read Pulse Train Command
This monitor reports the number of inputted pulses to the inputs CWP (CW pulse train) and CCWP (CCW
pulse train) of the connector CN2.
The format of inputted pulses shall comply with the setting of the parameter PC (Pulse
command).
This parameter may be used for checking the number of pulses inputted by a pulse train.
Refer to “7.3.3. Pulse Train Counter: Monitor RP” for details.
Category
Monitor
Format
RP data
Data range
<Readout>
–2 147 483 648 to
2 147 483 647 [pulse]
<Input>
–2 147 483 647 to
2 147 483 647 [pulse]
: Setting the data to zero (0) resets the monitor to zero (0).
The counting direction is up for the plus direction pulse train and down for the minus direction pulse train.
P
SC : (Factory use only)
This parameter is factory use only. Do not change the setting.
P
SF
: SoFt start
This parameter is used to set up the startup time of command under velocity control mode and torque
control mode.
Category
Parameter
Format
SF data
Data range 1
0
: Soft start invalid
Data range 2
0 to 100,000 [ms]
Shipping set
0
data denotes the time to reach the maximum command value.
The data denotes the time to reach 32767 in DC command of AC0.
The data denotes the time to reach the velocity command value or torque command value that is
set to +10[V] in the analog input command of AC1 and AC-1.
Содержание EDD Megatorque Motor
Страница 8: ... Blank Page ...
Страница 92: ...4 RS 232C Communication and USB Communication 4 16 Input the command WWC for cancellation of Multi monitor ...
Страница 146: ...6 Operation 6 38 Blank Page ...
Страница 184: ...7 Operational Function 7 38 Blank Page ...
Страница 211: ...8 More Advanced Function 8 27 ...
Страница 246: ...8 More Advanced Function 8 62 Blank Page ...
Страница 332: ...9 Details of Command and Parameter 9 86 Blank Page ...
Страница 340: ...10 Maintenance 10 8 Blank Page ...
Страница 364: ...11 Alarm and Warning 11 24 Blank Page ...