9. Details of Command and Parameter
— 9-81 —
P
ZAE : End Point of Zone A
This parameter sets the end point of the zone A at where the output ZONEA (Zone A) opens.
Refer to “8.3.1. In-zone Output: ZONEA, ZONEB, and ZONEC” for details.
The zone A starts from the setting of the parameter ZAS (Start point of zone A)in the counting
up direction (plus direction) of scale data and ends at the setting of the parameter ZAE (End
point of zone A).
Category
Parameter
Format 1
ZAE data
Format 2
ZAE /ST
: Sets the current position to the end point of the zone A.
Data range
0 to 2 621 439 [pulse]
Shipping set
0
Conditions to be
met
<In case of teaching by the ZAE/ST>
Alarm A0 (Position sensor error) is not occurring.
Alarm A1 (Absolute position error) is not occurring.
Alarm A4 (Over speed) is not occurring.
P
ZAW : Zone A Width
This parameter sets the minimum outputting time of the output ZONEA (Zone A).
Refer to “8.3.1. In-zone Output: ZONEA,ZONEB, and ZONEC” for details.
When the Motor passes a narrow zone in high speed, the time for outputting the ZONEA signal
gets shorter. The parameter ZAW is used for reliable detection of the output signal.
Category
Parameter
Format
ZAW data
Data range
0.0 to 10 000.0 [ms]
Shipping set
0.0
P
ZBS : Start Point of Zone B
This parameter sets the starting point of the zone B at where he output ZONEB (Zone B) closes.
Refer to “8.3.1. In-zone Output: ZONEA, ZONEB, and ZONEC” for details.
The zone B starts from the setting of the parameter ZBS (Start point of zone B) in the counting
up direction (plus direction) of scale data and ends at the setting of the parameter ZBE (End
point of zone B).
Category
Parameter
Format 1
ZBS data
Format 2
ZBS /ST
: Sets the current position to the start point of the zone B.
Data range
0 to 2 621 439 [pulse]
Shipping set
0
Conditions to be
met
<In case of teaching by the ZBS/ST>
Alarm A0 (Position sensor error) is not occurring.
Alarm A1 (Absolute position error) is not occurring.
Alarm A4 (Over speed) is not occurring.
Содержание EDD Megatorque Motor
Страница 8: ... Blank Page ...
Страница 92: ...4 RS 232C Communication and USB Communication 4 16 Input the command WWC for cancellation of Multi monitor ...
Страница 146: ...6 Operation 6 38 Blank Page ...
Страница 184: ...7 Operational Function 7 38 Blank Page ...
Страница 211: ...8 More Advanced Function 8 27 ...
Страница 246: ...8 More Advanced Function 8 62 Blank Page ...
Страница 332: ...9 Details of Command and Parameter 9 86 Blank Page ...
Страница 340: ...10 Maintenance 10 8 Blank Page ...
Страница 364: ...11 Alarm and Warning 11 24 Blank Page ...