8. More Advanced Function
— 8-59 —
8.9.2.5.
Readout of Parameter Settings and Internal State
Input as
?
+
Command name
+
Carriage return (0D
H
)
to read out a set value of parameter.
The example below is to read out the set value of the command VG. However, the System has another
command VGL that includes same two characters V and G. In such a case, the settings of the two
commands will be read out.
:
0A
H
0D
H
:?VG
VG0.5
VGL0.50
:_
Input (to Driver Unit)
0D
H
G
V
?
Readout (from Driver Unit)
(1)
20
H
0A
H
0D
H
G
V
?
5
.
0
G
V
Entered command
Readout of velocity gain
Waits for the next command.
(1)
Readout of velocity gain, lower
: 0D
H
0
5
20
H
.
0
L
G
V
: 0A
H
(2)
(2)
(3)
:
(3)
!
Caution : When the parameter MM is set to MM1, the prompt semicolon (:) is added
to the end of line. Input of [20
H
] is required every time the
prompt (;) appears.
For readout of internal stat, input as
Command name
+
Carriage return (0D
H
)
.
For an example, let’s read out the current position (in units of pulse).
0A
H
:TP5
TP100
:_
Input (to Driver Unit)
0D
H
P
T
Readout (from Driver Unit)
(1)
20
H
0A
H
0D
H
P
T
0D
H
0
0
1
P
Entered
command
Readout of current position data
Waits for the next command.
(1)
:
(2)
(2)
Содержание EDD Megatorque Motor
Страница 8: ... Blank Page ...
Страница 92: ...4 RS 232C Communication and USB Communication 4 16 Input the command WWC for cancellation of Multi monitor ...
Страница 146: ...6 Operation 6 38 Blank Page ...
Страница 184: ...7 Operational Function 7 38 Blank Page ...
Страница 211: ...8 More Advanced Function 8 27 ...
Страница 246: ...8 More Advanced Function 8 62 Blank Page ...
Страница 332: ...9 Details of Command and Parameter 9 86 Blank Page ...
Страница 340: ...10 Maintenance 10 8 Blank Page ...
Страница 364: ...11 Alarm and Warning 11 24 Blank Page ...