
2. Specifications
— 2-23 —
2.6.3. Cable Set
Caution : If you connect the cable to a moving part, be sure to use a flexible type
cable.
2.6.3.1.
Stationary Cable
Caution : Bending radius of a Motor cable (ø 8) and resolver cable (ø 8) shall be
R43 mm or over.
Caution : Do not add the stress (tension, vibration, etc) to the cable and the
connector. It causes the disconnection and the loose connection.
Fig 2-30: Cable Set (Fixed type: M-C0×××SDP03)
Dr
iv
er Uni
t s
id
e
Mo
tor s
ide
Motor Cable
Resolver Cable
2.6.3.2.
Flexible Cable
Caution : Do not move the following parts.
A range of 200 [mm] from the end face of the Motor side receptacle housing
A range of 200 [mm] from the end face of the Driver Unit side plug assembly and
connector header
Caution : The bending radius of a Motor cable (ø 8) and resolver cable (ø 8) shall
be R80 mm or over. The radius of cables at the connecting position shall
be R40 mm or over.
Caution : Do not add the stress (tension, vibration, etc) to the cable and the
connector. It causes the disconnection and the loose connection.
!
!
!
!
!
!
Содержание EDD Megatorque Motor
Страница 8: ... Blank Page ...
Страница 92: ...4 RS 232C Communication and USB Communication 4 16 Input the command WWC for cancellation of Multi monitor ...
Страница 146: ...6 Operation 6 38 Blank Page ...
Страница 184: ...7 Operational Function 7 38 Blank Page ...
Страница 211: ...8 More Advanced Function 8 27 ...
Страница 246: ...8 More Advanced Function 8 62 Blank Page ...
Страница 332: ...9 Details of Command and Parameter 9 86 Blank Page ...
Страница 340: ...10 Maintenance 10 8 Blank Page ...
Страница 364: ...11 Alarm and Warning 11 24 Blank Page ...