6. Operation
— 6-34 —
6.3.6.2.
RS-232C Communication Operation
In the velocity control mode and torque control operation, the Motor rotational velocity and output torque
can be directly controlled by the RS-232C communication command.
Setting of the parameter AC (AC0) enables the DC command.
Then, the Motor is controlled by the rotational velocity and the output torque proportional to the data
value.
:
DC10
:
_
C
D
ENT
(
data
)
Fig 6-24 shows the relationship between the DC command data, and the rotational velocity and output
torque.
Fig 6-24: Communication operation command, and Motor rotational velocity and output torque
Relationship between
communication command value
and rotational velocity
+
32 767
-
32 767
10 s
-1
-
10 s
-1
Operation
command
(DC)
Rotational velocity
Relationship between
communication command value
and output torque
+
32 767
-
32 767
-100%
100%
Operation
command
(DC)
Maximum torque
!
Caution
• Depending on the parameter DI setting, the polarity of the DC command is
reversed.
• The shipping set value of the parameter DI is "0."
(The CW direction viewed from the Motor rotor is count-up.)
• The rotational velocity of the Motor is limited depending the Motor type.
Содержание EDD Megatorque Motor
Страница 8: ... Blank Page ...
Страница 92: ...4 RS 232C Communication and USB Communication 4 16 Input the command WWC for cancellation of Multi monitor ...
Страница 146: ...6 Operation 6 38 Blank Page ...
Страница 184: ...7 Operational Function 7 38 Blank Page ...
Страница 211: ...8 More Advanced Function 8 27 ...
Страница 246: ...8 More Advanced Function 8 62 Blank Page ...
Страница 332: ...9 Details of Command and Parameter 9 86 Blank Page ...
Страница 340: ...10 Maintenance 10 8 Blank Page ...
Страница 364: ...11 Alarm and Warning 11 24 Blank Page ...