5. Tuning
— 5-10 —
5.3.2. Minor Tuning of Servo Gains
!
Danger : Take an appropriate precaution for a full turn of the Motor.
Minor tuning of servo loop gains
is required in the following cases.
When an automatic tuning (Tuning Level 1) is not successful.
The parameter LO (Load inertia) is manually inputted.
Use the parameter SG (Servo gain) for minor tuning of servo loop gains.
A higher SG setting improves the response to positioning command. However, the Motor tends
to vibrate when the SG setting is too high.
The minor tuning of servo loop gains automatically sets the following parameters that are related to the
servomechanism. Parameters are listed in the Table 5-5: Servo parameters set by the minor tuning of servo
loop gains.
Table 5-5: Servo parameters set by the minor tuning of servo loop gains.
Parameter
Description
PG
Position gain (position loop proportional gain)
VG
Velocity gain (velocity loop proportional gain)
When the automatic tuning is successfully completed, the parameter SG has been set automatically for
the estimated load inertia. Leave the setting as is and start the minor tuning of the parameter SG.
If the automatic tuning has not been performed or the automatic tuning has not been successful because
of an error, perform the following procedures before the minor tuning.
!
Caution :
When the parameter LO is manually set as described in “5.3.1 Input of
Load moment of Inertia
”, the parameters SG and FP (Primary
low- pass filter) are not set automatically. Set temporally the parameter
SG to “SG5” and the parameter FP to “FP200”, then start the minor
tuning.
1) Set the servo gain.
:
:
:
SG5
PG0.10;_
ENT
G
5
%
S
SP
SP
Press the SP key several times till the prompt “: (colon) ” appears on the bottom line.
2) Set the low-pass filter to 200 Hz.
:
:
:FP200
:
_
ENT
P
0
?
F
0
?
2
$
Содержание EDD Megatorque Motor
Страница 8: ... Blank Page ...
Страница 92: ...4 RS 232C Communication and USB Communication 4 16 Input the command WWC for cancellation of Multi monitor ...
Страница 146: ...6 Operation 6 38 Blank Page ...
Страница 184: ...7 Operational Function 7 38 Blank Page ...
Страница 211: ...8 More Advanced Function 8 27 ...
Страница 246: ...8 More Advanced Function 8 62 Blank Page ...
Страница 332: ...9 Details of Command and Parameter 9 86 Blank Page ...
Страница 340: ...10 Maintenance 10 8 Blank Page ...
Страница 364: ...11 Alarm and Warning 11 24 Blank Page ...