6. Operation
— 6-23 —
6.3.3. Pulse Train Command Positioning Operation
An input of pulse train command through the inputs of CWP (pulse train, CW) and CCW (pulse train,
CCW) of the CN2 connector (Input/Output) controls a positioning operation. The frequency of input pulse
determines rotational velocity while the total number of inputted pulse determines the rotation amount.
Fig 6-15: Pulse train command operation and resolution
CN2: CWP
CN2: CCWP
Positioning
command
Pulse counter
2 621 440
Parameter CR
Monitor RP
Parameter PC
PC0: CWP/CCWP
PC1: pulse/direction
PC4: øA/øB
PM: Filter of pulse train
input
1 [Mpps]
Table 6-9: Input/Output and parameters related to pulse train command positioning
Category
Name
(code)
Function
Initial
setting
Data range (description)
Unit
Con
tro
l
in
p
u
t
CWP
+
CW pulse train, (+) direction
–
The pulse train command rotates
the Motor in the plus direction.
Format of
pulse &
direction and
øA/øB
are also
available.
CWP
-
CW pulse train, (–) direction
–
CCWP
+
CCW pulse train, (+)
direction
–
The pulse train command rotates
the Motor in the minus direction.
CCWP
-
CCW pulse train, (–)
direction
–
Con
tro
l
o
u
tp
u
t
IPOS
Reports completion of
positioning.
–
Open: Positioning
uncompleted. Lost the
target position.
Closed: Positioning completed.
The target position
secured.
–
TEU
Reports that the position
error is under the threshold.
–
Open: Out of the threshold.
Closed: Cleared the threshold.
–
Pa
ra
m
e
te
r
CR
Resolution of pulse train
input.
2 621 440
0: 5 242 880 for one revolution
or 1 000 to 5 242 879
Count/revolution
PM
Filter of pulse train input
1
1,2, 4
Mpps
PC
Selects the format of pulse
train command.
0
0: CW/CCW
1: pulse/direction
4: øA/øB quadrupled
–
TEU
Threshold of the output
TEU.
0
0 to 2 621 439
pulse
M
o
n
ito
r
RP
Monitors the state of pulse
train input counter.
0
-2 147 483 648 to
2 147 483 647
Count
TN
Monitor the current position.
(Unit: CR)
–
0 to CR
-1
360
/parameter
CR
TNC
Monitors position command
(Unit: CR)
–
0 to CR
-1
: The password is required.
Содержание EDD Megatorque Motor
Страница 8: ... Blank Page ...
Страница 92: ...4 RS 232C Communication and USB Communication 4 16 Input the command WWC for cancellation of Multi monitor ...
Страница 146: ...6 Operation 6 38 Blank Page ...
Страница 184: ...7 Operational Function 7 38 Blank Page ...
Страница 211: ...8 More Advanced Function 8 27 ...
Страница 246: ...8 More Advanced Function 8 62 Blank Page ...
Страница 332: ...9 Details of Command and Parameter 9 86 Blank Page ...
Страница 340: ...10 Maintenance 10 8 Blank Page ...
Страница 364: ...11 Alarm and Warning 11 24 Blank Page ...