9. Details of Command and Parameter
— 9-2 —
9.1.4. Inhibited Operations in USB Communication
In EDD MegaTerm, the commands shown below cannot be used under specific conditions.
Table 9-3: Commands that cannot be used under specific conditions
Command
Meaning
MM is being executed in
EDD MegaTerm
Any command is being
executed in RS-232C
CH
Channel editing
No
Yes
PI
Control input editing
No
Yes
PO
Control output editing
No
Yes
AT
Auto Tuning
No
No
OP
Output Port Forced output
No
No
SI
System initialization
(only servo parameters)
No
No
SI/SY
System initialization
(all parameters except for AO)
No
No
SI/AL
System initialization
(all parameters)
No
No
JG/PL
Jogging operation (plus direction)
No
No
JG/MI
Jogging operation (minus direction)
No
No
HS/LS
Home limit sensor mounting position
adjustment
No
No
When a command is executed in the condition of “No”, an error message will be displayed.
Do not execute following operations in EDD MegaTerm.
Transferring to other screen when any command of Table 9-5 is being executed in the Terminal
screen.
Pressing the shutdown button when any command in Table 9-5 is being executed in the
Terminal editing screen, or disconnecting the USB cable.
The behavior of Driver Unit when conducting the above operations will be as follows.
Table 9-4: Behavior of Driver Unit when inhibited operations are conducted
Command
Meaning
Transferring to other screen while
command is being executed
Disconnecting USB cable while
command is being executed
/RP
Repeated display
Command cancel
Command cancel
/AJ
Adjusting
Command cancel
Command cancel
/WW
Multi-monitor
Command cancel
Command cancel
CH
Channel editing
Command cancel
Communication unavailable
(Rebooting of Driver Unit requiered)
PI
Control input editing
Command cancel
Communication unavailable
(Rebooting of Driver Unit requiered)
PO
Control output editing
Command cancel
Communication unavailable
(Rebooting of Driver Unit requiered)
AT
Auto tuning
Command cancel
Communication unavailable
(Rebooting of Driver Unit requiered)
Содержание EDD Megatorque Motor
Страница 8: ... Blank Page ...
Страница 92: ...4 RS 232C Communication and USB Communication 4 16 Input the command WWC for cancellation of Multi monitor ...
Страница 146: ...6 Operation 6 38 Blank Page ...
Страница 184: ...7 Operational Function 7 38 Blank Page ...
Страница 211: ...8 More Advanced Function 8 27 ...
Страница 246: ...8 More Advanced Function 8 62 Blank Page ...
Страница 332: ...9 Details of Command and Parameter 9 86 Blank Page ...
Страница 340: ...10 Maintenance 10 8 Blank Page ...
Страница 364: ...11 Alarm and Warning 11 24 Blank Page ...