8-2. OPERATION
8-2-1. OPERATION OF THE LOADER
A. Auto-run mode :
If you push the button "RUN", the program of file which is selected by Setup-00 "FILE#" is run
automatically. There are 16 files (00~15) and each file is composed of 96 steps.
If the setting value is 16, The file number to be run in automatic operation is determined by
external BCD input (input-13,12,11,10) from the master device (PLC, switches, etc.).
When the servo amplifier is in servo-on, It is possible to enter the auto-run mode.
If the Setup-44 "SERVO" ("auto servo on" function) is set in "1", it makes the servo amplifier to be
automatically servo-on before operation.
The output 0 ("running" monitor output) becomes on when the Setup-31 "O0/RN" is set in "1".
B. Home return mode :
If you push the button "HOME", the home return function is performed according to the method
set by Setup-13 "HFILE" as follows.
The complex home return provides an another home return function which requires complex motion
(general home, additional motion, in/out functions, etc.).
When the servo amplifier is in servo-on, It is possible to enter the home return mode.
If the Setup-44 "SERVO" ("auto servo on" function) is set in "1", it makes the servo amplifier to be
automatically servo-on before operation.
The output 4 ("homing" monitor output) becomes on during home return, and becomes off after the
end of home return, when the Setup-35 "O4/HM" is set in "1".
C. Ready :
If you push the button "READY", the motor amplifier is turned into servo-on if it is in off state.
Reversely, if it is already on state, the motor amplifier is turned into servo-off.
The servo amplifier should be in servo-on before any moving operation is performed.
If the Setup-44 "SERVO" ("auto servo on" function) is set in "1", it makes the servo amplifier to be
automatically servo-on regardless of "ready" button before any moving operation.
If the Setup-34 "O3/SO" is set in "1", the output 3 ("servo-on" monitor output) becomes on when
the servo amplifier is in servo-on state.
D. Program mode :
If you push the button "SHIFT+F1", you can select the program edit mode.
It makes the servo amplifier to be automatically servo-off.
E. Manual mode :
If you push the button "SHIFT+F2", you can select the manual mode.
The servo amplifier should be in servo-on before any manual operation is performed.
F. Setup parameter mode :
If you push the button "SHIFT+F3", you can select the setup parameter edit mode.
It makes the servo amplifier to be automatically servo-off.
G. Servo parameter mode :
If you push the button "SHIFT+F4", you can select the servo parameter edit mode.
It makes the servo amplifier to be automatically servo-off.
0
General home return
1 ~ 15
Program file number for complex home return (max. 50 step)
0 ~ 15
Setting value determines the file number.
16
External BCD input (input-13,12,11,10) determines the file number.