6-6. SPECIAL SERVO PARAMETERS
The special servo parameters have the items (motor constants, etc.) for factory setting.
The user can not set or change the special servo parameter.
No. Name
Description
Range
Min.
Max.
00 CURPG
* CURRENT P-GAIN
Used to set the P-gain for current loop.
1
1000
01
CURIG
* CURRENT I-GAIN
Used to set the I-gain for current loop.
1
1000
02
IFSCL
* MAXIMUM CURRENT
Used to set the maximum current.
1
9999
03
IRMAX
* RATED CURRENT
Used to set the rated current.
1
9999
04 REQUL
* MOTOR RESISTOR/PHASE
Used to set the resistance per phase.
1
9999
05
LEQUL
* MOTOR INDUCTANCE/PHASE
Used to set the inductance per phase.
1
9999
06 TQCON
* MOTOR TORQUE CONSTANT
Used to set the torque constant.
1
9999
07 JMCON
* MOTOR INERTIA
Used to set the motor inertia.
1
9999
08 BKEMF
* MOTOR BACK EMF
Used to set the motor back-emf.
1
9999
09
XXXXX
* RESERVED
0
9999
10 LCKTM
* LOCK TIME
Used for factory setting.
1
300
11 LCKTQ
* LOCK TORQUE
Used for factory setting.
1
100
12
~
15
XXXXX
* RESERVED
0
9999