12
C-12
* OUTPUT CHECK
Usage : used to check the output ports and wiring mistake.
Output selection: Select the output no.(00~07)
by UP/DOWN key.
Selected output no. is displayed.
Output on/off : The selected output is toggled.
( H: ON,
L: OFF )
13
C-13
* EXTERNAL ENCODER (MPG) CHECK
Check the external encoder A/B phase for auxiliary function.
The dot means the reverse(CCW) rotation.
If the dot is not displayed, it means the forward(CW) rotation.
Usage : used to check the external encoder A/B phase wiring mistake.
14
C-14
* PARAMETER INITIALIZATION
Used to initialize the parameter with factory setting value.
On the 'cccc' status, the parameter initialization is started.
The '----' status is displayed at the end of initialization.
Push the MODE key to return to the main check mode
Usage : used to check the servo amplifier at factory setting.