5-4. OPERATION OF THE SERVO KEY UNIT
A built-in servo key unit provides the cost-effective and convenient editing function without optional
loader. When the servo amplifier is in servo-off, It is possible to enter the setup parameter mode by
the servo key unit. Editing sequence is as follows.
Operation
Push the MODE key to change from "status display" to
mode selection level.
1. The pre-saved mode is displayed at LED.
Each modes are scrolled sequentially by UP/DOWN
key.
2. Select the "SEt" mode and push the SET key.
3. The start no. of setup parameter is displayed.
Each parameter no. is scrolled sequentially by
UP/DOWN key. (P-00 ~ P-79)
Stop the display at the parameter no. to be changed.
If you push the MODE key, the system returns to
the run ready state.
4. Push the SET key to edit parameter.
The 1st figure shows the sign of value.
"P" means plus value and "-" means minus value.
Next 3 figures shows the upper parameter value that
is above 1000's of that.
The sign (1st) figure is toggled by the UP key.
5. Select the digit of LED sequentially by DOWN key.
The value of selected digit is blinking.
6. Push the UP key, the value of selected figure is
increased 1 by 1 as the ring counter.
If the value changed, the dots are disappeared.
Repeat the operation of 5 and 6.
For the cancellation of the changing value,
push the MODE key then return to the level 3.
Push the SET key to edit value of below 100's.
The 1st figure shows "L" that means the lower side
of parameter.
Next 3 figures shows the value that is below 100's.
7. Select the figure of LED sequentially by DOWN key.
The value of selected figure is blinking.
8. Push the UP key, the value of selected figure is
increased 1 by 1 as the ring counter.
If the value changed, the dots are disappeared.
Repeat the operation of 7 and 8.
For the cancellation of the changing value,
push the MODE key then return to the level 3.
9. Push the SET key to save the setting values.
If the setting values are in ranges, they are saved
and return to the level 3.
The parameter no. is auto-increased 1 by 1.
If the setting values are out of ranges, they are not
saved and return to the level 4 for re-edit.
Содержание Tango-B series
Страница 16: ...1 6 3 DIMENSIONS OF BASE MOUNT TYPE1 TANGO B24 B30 B35 1 6 4 DIMENSIONS OF BASE MOUNT TYPE2 TANGO B40 B50 B75 ...
Страница 68: ......
Страница 111: ...APPENDIX ...