Standard System Configuration
3-35
Part 1056418-07
E
2019 Nordson Corporation
Other Buttons:
The buttons on the bottom of the desktop are minimized
application windows that may be used to view diagnostic or status
information for selected programs.
Sys Restart:
Performs a restart of the primary iControl program and user
interface. The only program that remains running is the CAN driver.
iControl:
Performs a restart of the iControl user interface only.
Shutdown:
Displays the Shutdown dialog shown in Figure 3-32.
Utilities:
Displays a menu of file system tools. These tools should only be
used with the direction of Nordson technical support.
Configuration:
Displays a menu of configuration tools. These tools should
only be used with the direction of Nordson technical support.
Time/Date:
Use this utility to set the time and date.
Screensaver:
Use this utility to enable or disable the screen saver and
power saver. The default settings are screen saver disabled and power
saver set to shut off the LCD backlights after 1 hour of no activity. Touching
the screen will turn on the backlights and make the screen visible again.
NOTE:
If a system failure should occur when the screen backlights are off,
the screen will not turn back on. If this happens you must cycle console
power to restart the system. Instruct all operators on the operation of the
screen saver. The power saver can be disabled by “unchecking” the screen
shutdown option on the power saver tab.
Network:
Provides access to Ethernet settings. Most settings are typically
configured from the iControl user interface, but this utility includes
specialized settings. These settings should only be changed with the
direction of Nordson technical support.
Calib:
Starts the touch screen calibration process. Refer to
Touch Screen
Calibration
below.
System Monitor:
Indicates status of system components.
Touch Screen Calibration
See Figure 3-32. Use the calibration procedure to recalibrate your touch
screen. The calibration values are stored on the program card.
S
If you install a program card that has not been used before there will be
no calibration file on the card, so the system will automatically start the
calibration procedure on bootup.
S
If you install a program card that was previously used on another
iControl console, you MUST perform the
Calibration with a Mouse
procedure in the iControl hardware manual 1044158 or 1056419.
Touch the
CAL
(previous versions)
or CALIB
button to start the procedure.
The calibration instructions appear on the screen. Follow the instructions
exactly.
Содержание Encore iControl 2
Страница 8: ...Table of Contents vi Part 1056418 07 E 2019 Nordson Corporation...
Страница 10: ...Change Record viii Part 1056418 07 E 2019 Nordson Corporation...
Страница 116: ...Positioner Preset Settings 6 8 Part 1056418 07 E 2019 Nordson Corporation...
Страница 142: ...Operation 8 20 Part 1056418 07 E 2019 Nordson Corporation...
Страница 168: ...Configuration and Preset Records 10 12 Part 1056418 07 E 2019 Nordson Corporation...