Monitoring Operation
9-5
Part 1056418-07
E
2019 Nordson Corporation
Single Gun Status
See Figure 9-3. Touch a
Gun
button to open the Gun Control screen for
that gun. The Gun Status area of the screen shows you the:
S
part/preset being sprayed
S
flow-rate air flow (dark blue) and atomizing air flow (light blue) for
standard guns
S
powder flow setpoint and actual pump air flow (dark blue) and pattern air
flow (light blue) for Prodigy guns
S
electrostatic outputs
S
gun type
S
fault code, if a gun-related fault occurs
S
percent adjust status: If
Δ
% (delta %) symbols appear below the flow
bar graphs, then the flow is being adjusted automatically with the
Percent Adjust function.
NOTE:
Gun-related faults are faults that occur in the gun’s voltage
multiplier, cable, gun control card, or iFlow module. If a gun-related fault
occurs, the gun button will blink yellow.
Part
Being
Sprayed
Percent
Adjust
ON Indicator
Flow Rate
Air Flow
Atomizing
Air Flow
m
A Output
kV Output
Gun
Hourmeter
Standard Guns
Prodigy Guns
Fault Code
Powder
Flow
Pattern
Air Flow
Powder
Flow
Setpoint
Figure 9-3
Global Status Screen
Gun Hourmeter
The
Gun Hourmeter
button on the Gun Control screen opens the
hourmeter screen for the gun. This screen displays
S
gun and pump hours on since the last maintenance reset.
S
maintenance hours for the guns (also for Prodigy pumps).
S
gun and pump total hours.
Gun and pump maintenance hours are reset from the Configure Hourmeter
screen.
Содержание Encore iControl 2
Страница 8: ...Table of Contents vi Part 1056418 07 E 2019 Nordson Corporation...
Страница 10: ...Change Record viii Part 1056418 07 E 2019 Nordson Corporation...
Страница 116: ...Positioner Preset Settings 6 8 Part 1056418 07 E 2019 Nordson Corporation...
Страница 142: ...Operation 8 20 Part 1056418 07 E 2019 Nordson Corporation...
Страница 168: ...Configuration and Preset Records 10 12 Part 1056418 07 E 2019 Nordson Corporation...