Monitoring Operation
9-9
Part 1056418-07
E
2019 Nordson Corporation
To reset a selected fault, touch the
Reset Selected Button
. If the problem
that caused the fault is not corrected, the fault will reappear.
Touch the
Erase All Messages Button
to clear routine system messages
from the alarm screen.
To display the alarm log, touch the
Alarm Log
Button
. Touch the scroll bar
arrows to scroll the screen horizontally or vertically.
Reset All
Erase All
Messages
Open Alarm Log
Help
Reset
Selected
Alarm Screen
Alarm Log
The Alarm Log
fstatus
log files list all faults, resets, and status messages
for the current day. Use the drop-down menu to open previous fstatus logs
for up to 5 days.
Other log files include
errors.dat
, which lists errors and information
concerning the operator interface,
syserrors.log
, which lists errors and
information concerning the iControl system manager, and
CANstatus.log
,
which lists CAN messages when the system is configured to not log them
into the normal Alarm log. Additional files may be listed. The information in
these log files may be used by Nordson field engineers or technical support
staff.
Delete Open Log Button:
To delete a log, open it and then touch the
delete button.
Close Alarm Log Button:
Returns you to the Alarm screen.
Содержание Encore iControl 2
Страница 8: ...Table of Contents vi Part 1056418 07 E 2019 Nordson Corporation...
Страница 10: ...Change Record viii Part 1056418 07 E 2019 Nordson Corporation...
Страница 116: ...Positioner Preset Settings 6 8 Part 1056418 07 E 2019 Nordson Corporation...
Страница 142: ...Operation 8 20 Part 1056418 07 E 2019 Nordson Corporation...
Страница 168: ...Configuration and Preset Records 10 12 Part 1056418 07 E 2019 Nordson Corporation...