Positioner Preset Settings
6-2
Part 1056418-07
E
2019 Nordson Corporation
Positioner Preset Settings
See Figure 6-1. To set up a preset for a positioner:
1. Use the
Preset Selector
to select a preset number first. All settings you
make apply to the selected preset. The preset settings for each
positioner are displayed on the screen.
NOTE:
If no changes have been made to the preset settings since the
screen was opened, the
Not Modified
icon is displayed. If you make a
change, the
Modified
icon is displayed instead.
2. If you want to view the
Default Settings
for a positioner, use the
Positioner Selector
. The default settings are displayed in the row to
the right of the selector.
3. Set
Lead
and
Lag
distances for gun moving.
Lead:
Distance from the guns to the leading edge of the part. At the
lead the guns are moved to the position setting.
S
A positive lead moves the guns
BEFORE
the leading edge of the
part reaches the guns.
S
A negative lead moves the guns
AFTER
the leading edge of the part
reaches the guns.
Lag:
Distance from the guns to the trailing edge of the part to the guns.
At this setting, the guns are moved in or out.
S
A positive lag moves the guns
AFTER
the trailing edge of the part
passes the guns.
S
A negative lag moves the guns
BEFORE
the trailing edge of the part
passes the guns.
4. Set the
Positioning Mode
to
Fixed
or
Variable
with the F/V mode
button.
Variable Positioning:
Gun-to-part distance to maintain while the part is
moving past the guns (contouring). This is the default positioning
method.
Fixed Positioning:
Position measured from zero (forward limit switch).
When a part with a fixed position setting arrives, the positioner moves to
the fixed position and remains there until a new part arrives with either:
S
no preset move settings (default settings are used) or
S
different preset move settings.
Содержание Encore iControl 2
Страница 8: ...Table of Contents vi Part 1056418 07 E 2019 Nordson Corporation...
Страница 10: ...Change Record viii Part 1056418 07 E 2019 Nordson Corporation...
Страница 116: ...Positioner Preset Settings 6 8 Part 1056418 07 E 2019 Nordson Corporation...
Страница 142: ...Operation 8 20 Part 1056418 07 E 2019 Nordson Corporation...
Страница 168: ...Configuration and Preset Records 10 12 Part 1056418 07 E 2019 Nordson Corporation...