Operation
8-9
Part 1056418-07
E
2019 Nordson Corporation
Percent Adjust Functions
See Figure 8-8. Two percent adjust functions are available to the operator
from the Main Screen: Global Percent Adjust and Conveyor Speed Percent
Adjust.
Both functions allow powder flow and fan pattern adjustments to be made
on the fly. The Global Percent Adjust applies to all guns immediately
whenever any value other than zero is entered. Conveyor Speed Percent
Adjust applies to all guns also, but synchronizes the adjustments with
conveyor speed.
The adjustments increase or decrease the preset flow settings by a
percentage of each setting. For standard guns, flow-rate and atomizing air
flow are adjusted. For Prodigy guns, powder flow and pattern air flow are
adjusted.
When Percent Adjust is on the Percent Adjust button on the main screen
button bar turns green. %
Δ
icons also appear on the Gun Control screens
to indicate that the outputs are being adjusted. Any settings you make on
this control screen are stored on the program card and saved if you shut
down the system.
Percent Adjust Additive Effects
The percent adjust functions are additive variables. In other words, if
settings are made for Reciprocator Stroke Length Percent Adjust,
Reciprocator Preset Percent Adjust, Global Percent Adjust, and Conveyor
Speed Percent Adjust, then all the percentages are added together (when
active) to arrive at a final adjustment factor.
For example, if Global = 5%, Conveyor = 5%, Reciprocator Preset = 5%,
and Reciprocator Stroke Length = 5%, then if all functions are active the
total percent adjust = 20%.
If Global = 5 and Conveyor =
−
5, then the total adjustment = 0.
Refer to
Section 7
,
Reciprocator Presets
for information on the Reciprocator
Preset Percent Adjust function and
Section 4, Positioner/Reciprocator
Configuration
for information on the Reciprocator Stroke Length Percent
Adjust function.
Global Percent Adjust
The percentage you enter takes effect immediately, for all presets. Positive
values increase flow and negative values decrease flow. Setting the values
to zero turns Global Percent Adjust off.
The
Percent Adjust Limit
prevents the additive effect from increasing the
flow-rate and atomizing air percent adjust beyond the value entered.
Содержание Encore iControl 2
Страница 8: ...Table of Contents vi Part 1056418 07 E 2019 Nordson Corporation...
Страница 10: ...Change Record viii Part 1056418 07 E 2019 Nordson Corporation...
Страница 116: ...Positioner Preset Settings 6 8 Part 1056418 07 E 2019 Nordson Corporation...
Страница 142: ...Operation 8 20 Part 1056418 07 E 2019 Nordson Corporation...
Страница 168: ...Configuration and Preset Records 10 12 Part 1056418 07 E 2019 Nordson Corporation...