Standard System Configuration
3-12
Part 1056418-07
E
2019 Nordson Corporation
Digital Zone Configuration
PE
radio button, then enter the
number of
zones
(1 to 8).
NOTE:
Selecting PE does not disable an analog scanner if one is present.
Analog Zone Configuration
Analog scanners must be supplied and configured by Nordson Corporation.
NOTE:
Before performing the following steps, go to Section 4 and
configure the Ethernet network, then configure a vertical analog scanner.
1. See Figure 3-9. Select the
DIM
radio button, then the
Configure
button.
The Analog Zone Scanner screen opens.
DIM
Configure
Zones
Auto-Zero
2
3
4
5
6
7
8
1
8
16
24
32
40
48
56
72
Zones
Zone Height
032
Figure 3-9
Configuring Analog Scanners for Zone Detection
2. For each zone, enter the distance in inches or millimeters from the top of
the scanner to the bottom of the zone. This screen shows a 72-inch
scanner divided into 8 zones.
Any unused scanner length is automatically added to the last zone
configured. Zone 8 is 72 inches long instead of 64 inches because the
leftover 8 inches is added.
NOTE:
A low-hung part that occupies zones 5
−
8 will trigger guns assigned
to zones 1
−
4 as well. To prevent this from happening, create a preset for
the part with the zone set to zero for the guns in zones 1
−
4 so that they will
not be triggered on.
Содержание Encore iControl 2
Страница 8: ...Table of Contents vi Part 1056418 07 E 2019 Nordson Corporation...
Страница 10: ...Change Record viii Part 1056418 07 E 2019 Nordson Corporation...
Страница 116: ...Positioner Preset Settings 6 8 Part 1056418 07 E 2019 Nordson Corporation...
Страница 142: ...Operation 8 20 Part 1056418 07 E 2019 Nordson Corporation...
Страница 168: ...Configuration and Preset Records 10 12 Part 1056418 07 E 2019 Nordson Corporation...