Ethernet and Gun Mover Configuration
4-23
Part 1056418-07
E
2019 Nordson Corporation
Fixed Mode
See Figure 4-16. In fixed mode, the stroke length is controlled by the
turn-around points, without regard for the part height. The gun trigger points
are controlled to vary the spray length with the part height.
NOTE:
In fixed mode, the Air Flow Percent Adjust function is not available.
Top and bottom turn-around limits
−
These limits set the stroke length,
and are measured from Reciprocator Home. Set the top turn-around limit
below the soft top limit, and the bottom turn-around limit above the soft
bottom limit.
Gun On/Off Trigger Points
−
These are the distances
above and below
the part edge to trigger the guns on and off on the downstroke and
upstroke. They are similar to lead and lag settings:
S
Positive trigger points extend the spray pattern (see Figure 4-17).
S
Negative trigger points restrict the spray pattern (see Figure 4-18).
S
If the trigger points are set to zero the guns turn on and off at the part
edges.
NOTE:
These settings can be modified from the
Reciprocator Control
screens
, accessible from the Main screen (refer to Section 8). The Control
screens also provide access to the
Lap Calculator
screens. Use the lap
calculator to experiment with different settings.
Guns On Downstroke
Guns Off Upstroke
Top Turn-Around Limit
Bottom Turn-Around Limit
Guns Off Downstroke
Guns On Upstroke
Reciprocator Speed
(Used for Fixed No Sync mode only)
Figure 4-16 Fixed Mode Settings
Содержание Encore iControl 2
Страница 8: ...Table of Contents vi Part 1056418 07 E 2019 Nordson Corporation...
Страница 10: ...Change Record viii Part 1056418 07 E 2019 Nordson Corporation...
Страница 116: ...Positioner Preset Settings 6 8 Part 1056418 07 E 2019 Nordson Corporation...
Страница 142: ...Operation 8 20 Part 1056418 07 E 2019 Nordson Corporation...
Страница 168: ...Configuration and Preset Records 10 12 Part 1056418 07 E 2019 Nordson Corporation...