Standard System Configuration
3-17
Part 1056418-07
E
2019 Nordson Corporation
Encoder Configuration
See Figure 3-2. Touch the
Encoder Configure
button on the System
Configuration screen to open the Encoder Configuration screen. Use this
screen to configure the conveyor encoder signal and set the encoder
resolution, or select the Clock option.
Encoder Resolution:
Number of encoder pulses per unit of movement.
A resolution of 1.00 is 1 pulse per 1 inch or 1 millimeter.
NOTE:
The encoder resolution limits the conveyor speed at which the
iControl system can track parts. A resolution of 1.0 inch limits the conveyor
speed to 50 ft/min. (10 Hz), a resolution of 0.100 inch limits the speed to 10
ft/min.
Encoder
Configuration
and
Clock Option
Calculate
Resolution
Enter Known
Resolution
041
Figure 3-14 Encoder Configuration Screen
Encoder Pulse Configuration
X2:
Multiplies the encoder pulses by 2, for a finer resolution and more
accurate triggering.
P
2:
Divides the encoder pulses by 2, for a coarser resolution.
X1:
Uses the encoder pulses as is. This is the default configuration.
Clock Option
If your system does not have an encoder, or the encoder malfunctions and
you do not have a replacement, you can select the
CK
(clock) option and
enter the conveyor speed. This is not as accurate a part tracking method as
using an encoder.
Содержание Encore iControl 2
Страница 8: ...Table of Contents vi Part 1056418 07 E 2019 Nordson Corporation...
Страница 10: ...Change Record viii Part 1056418 07 E 2019 Nordson Corporation...
Страница 116: ...Positioner Preset Settings 6 8 Part 1056418 07 E 2019 Nordson Corporation...
Страница 142: ...Operation 8 20 Part 1056418 07 E 2019 Nordson Corporation...
Страница 168: ...Configuration and Preset Records 10 12 Part 1056418 07 E 2019 Nordson Corporation...