Standard System Configuration
3-8
Part 1056418-07
E
2019 Nordson Corporation
Zone Configuration
Use the following procedures to configure the devices and inputs used for
zone detection. Refer to Section 4 for instructions on configuring analog
scanners to detect part height and width for positioners and reciprocators.
See Figure 3-2. Touch the
Photoeye and Scanner Configure
button on
the System Configuration screen to open the Photoeye and Scanner
Configuration screen.
Zone Overview
Gun triggering is accomplished by dividing the area in front of the guns into
vertical zones, so that as a part passes in front of a gun it is triggered on
and off. Photoeyes or scanners (light curtains) are used to detect both the
length of the parts and the zones the part occupies.
Zone Configuration
(Digital)
Zone Filter
Zone Configuration
(Analog)
Direct Triggering
Option
012
Figure 3-4
Zone Photoeye and Scanner Configuration Screen
Digital Zone Inputs:
Photoeyes or discrete scanners provide an 8-bit
binary signal to the 8 digital zone inputs provided in the iControl hardware.
They are connected to the iControl system by the discrete 25 conductor
cable.
Analog Zone Inputs:
Analog scanners can also be used for zone
detection. These scanners are typically used only if the system also
includes reciprocators, which require them to detect part height, or when an
iControl system is retrofitted into an existing system with analog scanners.
Содержание Encore iControl 2
Страница 8: ...Table of Contents vi Part 1056418 07 E 2019 Nordson Corporation...
Страница 10: ...Change Record viii Part 1056418 07 E 2019 Nordson Corporation...
Страница 116: ...Positioner Preset Settings 6 8 Part 1056418 07 E 2019 Nordson Corporation...
Страница 142: ...Operation 8 20 Part 1056418 07 E 2019 Nordson Corporation...
Страница 168: ...Configuration and Preset Records 10 12 Part 1056418 07 E 2019 Nordson Corporation...