Ethernet and Gun Mover Configuration
4-22
Part 1056418-07
E
2019 Nordson Corporation
Application-Specific Reciprocator Settings
Operation Mode Settings
Fixed Stroke, synchronized with conveyor
Variable Stroke, synchronized with conveyor
Variable Stroke, no synchronization
Fixed Stroke, no synchronization
Oscillator mode (only valid with a Fixed Mode)
Figure 4-14 Reciprocator Operation Mode Settings
Reciprocator Speed Settings
If a synchronization mode is selected, then the reciprocator speed is
calculated using the conveyor speed, stroke length, number of laps, number
of guns, and pattern width.
Without synchronization the reciprocator speed is controlled by the mode’s
speed setting. Speed can set in
Strokes per minute
, or
Feet per minute
.
The speed setting cannot exceed the maximum speed setting.
NOTE:
The strokes per minute setting are approximate. The actual strokes
per minute will vary with the length of the stroke. Shorter strokes will result
in larger errors because the machine does not have sufficient time running
at full speed.
Figure 4-15 Reciprocator Speed Settings
Содержание Encore iControl 2
Страница 8: ...Table of Contents vi Part 1056418 07 E 2019 Nordson Corporation...
Страница 10: ...Change Record viii Part 1056418 07 E 2019 Nordson Corporation...
Страница 116: ...Positioner Preset Settings 6 8 Part 1056418 07 E 2019 Nordson Corporation...
Страница 142: ...Operation 8 20 Part 1056418 07 E 2019 Nordson Corporation...
Страница 168: ...Configuration and Preset Records 10 12 Part 1056418 07 E 2019 Nordson Corporation...