Ethernet and Gun Mover Configuration
4-10
Part 1056418-07
E
2019 Nordson Corporation
Setting Zero and Home Positions
1. Set the positioner mode to
Manual
.
2. Set Zero and Home reference positions:
a. Jog the positioner forward to the forward limit switch (all the way
down for a top-down positioner, all the way up for a bottom-up
positioner). The limit switch icon should appear and the current
position should read 0.
b. Jog the positioner back to the rear limit switch (all the way up for a
top-down positioner, all the way down for a bottom-up positioner).
The limit switch icon should appear and the current position should
be the same as the positioner travel length. This is the Home
position.
NOTE:
Set the Zero and Home positions on initial startup and whenever
the positioner carriage is moved and the positioner I/O controller is turned
off. Auto mode is not allowed until the zero position is established. If the
zero position is not established and the positioner is set to Auto mode, the
positioner will automatically go to the the Home position.
Standard Positioner Configuration Settings
The following table describes the standard positioner configuration settings.
Item numbers in parenthesis correspond to the item numbers in Figure 4-5.
These settings apply to both horizontal or vertical positioners except where
noted.
NOTE:
Acceleration, deceleration and speed values are fixed and set at
the positioner motor speed controller. Only a Nordson engineer should
change these values.
Manual Positioner Operation:
If the positioners will only be operated
manually, then the only settings required are to select the Clean Only option
and set the Orientation.
Standard Positioner Configuration Settings
Orientation
(2)
Select the side of the booth the positioner is physically located on
(right or left). For vertical positioners, select Top-Down (T) or
Bottom-Up (B).
NOTE:
For horizontal and vertical positioners, the Main screen
changes to match the right/left settings for positioners 1
−
4. The
control screen for positioner 1 will control physical positioner 1 if the
node configuration was done in the correct order.
Gun Separation
(11)
If guns are mounted in a straight vertical array, such as on a fixed
gun stand or oscillator, enter the gun width. If the guns are
staggered then enter the width of the array.
If the guns are mounted in a
horizontal array, such as on a
reciprocator, enter the width of the array.
Continued...
Содержание Encore iControl 2
Страница 8: ...Table of Contents vi Part 1056418 07 E 2019 Nordson Corporation...
Страница 10: ...Change Record viii Part 1056418 07 E 2019 Nordson Corporation...
Страница 116: ...Positioner Preset Settings 6 8 Part 1056418 07 E 2019 Nordson Corporation...
Страница 142: ...Operation 8 20 Part 1056418 07 E 2019 Nordson Corporation...
Страница 168: ...Configuration and Preset Records 10 12 Part 1056418 07 E 2019 Nordson Corporation...