Ethernet and Gun Mover Configuration
4-29
Part 1056418-07
E
2019 Nordson Corporation
Single In/Out Positioner Scanner Configuration
See Figure 4-24. Use this procedure to configure a single horizontally
mounted scanner providing part width data to in/out positioners. The
scanner emitter-receiver pair are mounted above the conveyor rail and
below the parts. The scanner cable end must be oriented as shown on the
configuration screen. Cable end orientation is important because of the way
the scanner signal is read.
NOTE:
The scanner controller must be configured to ignore the conveyor.
Scanner controllers are typically programmed per the application
specifications before the system is shipped. Refer to your system drawings
for installation specifications.
Enter the following values for the scanner:
A:
Length of the scanner.
B:
The width of the conveyor left and right of the scanner centerline.
C:
Distance from the first scanner beam (cable end) to the conveyor
centerline.
A
B
C
Figure 4-24 SIngle Scanner Configuration for In/Out Positioners