Standard System Configuration
3-31
Part 1056418-07
E
2019 Nordson Corporation
Data Backup
Use the Data Backup utility to make a copy of your user data after you
configure your system and set up and test presets for your parts (refer to
the sections on Presets), or any time you make changes that you want to
save.
During the backup operation, all data on the user data card is copied to the
program card, and then written back to the data card when the system
reboots. Any data on the card in the user data slot is overwritten. All data
in iControl memory is written to the program card, then restored on reboot.
CAUTION:
You
MUST
do a complete system shutdown then cycle console
power and allow the system to reboot to complete the backup process. If
you cancel the program shutdown or select reboot, then you have not made
a backup and any changes made since the last backup will be lost.
NOTE:
Approved cards are SanDisk, Toshiba, PNY, and Memorex 128 Mb
(minimum) CompactFlash cards. Do not use unapproved cards. For more
information contact your Nordson representative.
CAUTION:
Do not remove the CompactFlash cards while console power is
on. Doing so will corrupt the data on the card.
1. Touch the
Backup Data
button on the System Configuration screen to
open the Data Backup screen:
Program
Shutdown
Start
Figure 3-29 Data Back Screen
2. Touch the
OK
button to start the backup operation. The stop watch
cursor is displayed during the backup operation.
3. When the
Program Shutdown
button is activated, touch it to continue
the process. Wait until the iControl program shuts down, then choose
Shut down system
on the operating system dialog box. Refer to
Program Shutdown
4. Turn off console power at the switch on the rear panel.
5. See Figure 3-30. Open the enclosure door and press the eject button
next to the data card slot. Remove the user data card.
Содержание Encore iControl 2
Страница 8: ...Table of Contents vi Part 1056418 07 E 2019 Nordson Corporation...
Страница 10: ...Change Record viii Part 1056418 07 E 2019 Nordson Corporation...
Страница 116: ...Positioner Preset Settings 6 8 Part 1056418 07 E 2019 Nordson Corporation...
Страница 142: ...Operation 8 20 Part 1056418 07 E 2019 Nordson Corporation...
Страница 168: ...Configuration and Preset Records 10 12 Part 1056418 07 E 2019 Nordson Corporation...