Standard System Configuration
3-10
Part 1056418-07
E
2019 Nordson Corporation
Digital Zone Triggering
(contd)
Zone 1
Zone 2
Zone 3
Zone 4
Conveyor Movement
Part 4
4
1
2
3
5
6
7
8
4
1
2
3
5
6
7
8
Zone Photoeyes
or Discrete Scanners
Zone 5
Zone 6
Zone 7
Zone 8
Leading
Edge
Trailing
Edge
Part 4
Spray Guns
8
Powder Spraying
Figure 3-6
Zone Example with Open Part
Analog Zone Triggering
See Figure 3-7. Analog scanners read from top down and from bottom up.
The iControl system uses the top-down analog signal for zone detection and
the bottom up signal for reciprocator control. Each zone is measured from
the top of the scanner, so a part automatically occupies all the zones from
the bottom edge of the part to the top of the scanner.
The disadvantage of using an analog scanner for zone triggering is that a
low hung part will cause all the guns assigned to the zones above the top
edge of the part to be triggered on.
To avoid triggering on the guns above the top edge of the part, create a
spray preset for the part with the zones set to zero for those guns.
This drawback also means that the guns in front of an open area of a part
will not be triggered off, but will continue to spray.
Содержание Encore iControl 2
Страница 8: ...Table of Contents vi Part 1056418 07 E 2019 Nordson Corporation...
Страница 10: ...Change Record viii Part 1056418 07 E 2019 Nordson Corporation...
Страница 116: ...Positioner Preset Settings 6 8 Part 1056418 07 E 2019 Nordson Corporation...
Страница 142: ...Operation 8 20 Part 1056418 07 E 2019 Nordson Corporation...
Страница 168: ...Configuration and Preset Records 10 12 Part 1056418 07 E 2019 Nordson Corporation...