Ethernet and Gun Mover Configuration
4-13
Part 1056418-07
E
2019 Nordson Corporation
To calculate the gun-to-conveyor centerline offset, measure the distance
from the booth floor to the gun tip with the positioner fully extended, and the
distance from the booth floor to the location of the appropriate beam (LBB
for Bottom-Up, FBB for Top-Down) on the scanner. The difference between
these values is the
Gun-to-Conveyor Centerline
value. For example:
Bottom-Up positioner:
The guns are 65 inches from the floor at full up.
The topmost beam (LBB) of the scanner is 108 inches from the floor. The
gun-to-conveyor centerline value is 108
−
65=43.
Top-Down positioner:
The guns are 85 inches from the floor at full down.
The bottommost beam (FBB) of the scanner is 36 inches from the floor.
The gun-to-conveyor centerline value is 85
−
36=49.
Top-Down
Positioner
Bottom-Up
Positioner
With Dual Scanners
0
Top-Down
Positioner
(FBB)
Bottom-Up
Positioner
(LBB)
LBB
FBB
LBB
FBB
B
A
0
With Single Scanner
A = Bottom-Up
B = Top-Down
Gun-to-Conveyor
Centerline Offset
Gun-to-Conveyor
Centerline Offset
FBB
LBB
A = Bottom-Up
B = Top-Down
B
A
LBB
FBB
LBB
FBB
Vertical Positioner Configuration (View from Front of Booth)
Содержание Encore iControl 2
Страница 8: ...Table of Contents vi Part 1056418 07 E 2019 Nordson Corporation...
Страница 10: ...Change Record viii Part 1056418 07 E 2019 Nordson Corporation...
Страница 116: ...Positioner Preset Settings 6 8 Part 1056418 07 E 2019 Nordson Corporation...
Страница 142: ...Operation 8 20 Part 1056418 07 E 2019 Nordson Corporation...
Страница 168: ...Configuration and Preset Records 10 12 Part 1056418 07 E 2019 Nordson Corporation...