Standard System Configuration
3-23
Part 1056418-07
E
2019 Nordson Corporation
Triggering Rules
(contd)
Lag Priority:
This rule mandates that the lag of the previous part continues
until complete or the leading edge of the next part is reached.
Previous Part
Preset 21
Next Part
Preset 18
Preset 18 Starts Spraying Here
Lag
Lead
Lag
Lead
Direction of Travel
Figure 3-20 Lag Priority Triggering Rule
Split Priority:
This rule mandates that if the lead of the next part overlaps
the lag of the previous part, the lead and lag are split evenly.
Previous Part
Preset 21
Next Part
Preset 18
Preset 18 Starts Spraying Here
Lag
Lead
Lag
Lead
Direction of Travel
Preset 18 Starts Spraying Here
Previous Part
Preset 21
Next Part
Preset 18
Lead
Lag
Lead
Direction of Travel
Lag
Figure 3-21 Split Priority Triggering Rule