Positioner Preset Settings
6-3
Part 1056418-07
E
2019 Nordson Corporation
Preset Selector
Copy
Keypad
Save
Lead
Lag
Fixed/Variable
Mode Toggle
Fixed
Position
Variable
Position
Default
Settings
for Selected
Positioner
Positioner
Selector
Not Modified
Icon
Modified Icon
Positioners
Positioner 1
Preset Settings
Positioner 2
Preset Settings
Preset Settings
Copy Selection
x
Reset to
Defaults
Figure 6-1
Spray Gun Control Screen
Copying Preset Settings
The
Copy
button copies the selected preset settings from positioner 1 to the
rest of the positioners.
To select a setting to copy, touch the setting label. When selected, an X
appears in the selection box on the label.
Saving Preset Settings
The
Save
button saves the preset settings to the user database. If you
close the screen without touching the save button, you will be prompted to
save or cancel your changes.
Reset to Defaults
The
Reset
button clears the values in the selected preset. The positioner
will then use the configured default values for that preset. Refer to
Positioner Configuration
in Section 4.